(2) Manual Override 

To keep the  lights on regardless of the motion,  you can 
override  the  automatic  operation.    To  enable  Manual 
Override  mode,  first  ensure  that  the  lights  are  on  and 
then turn the wall switch off and on twice (off-on, off-on) 
within  3  seconds.    The  interval  between  the  first  and 
second operation must be within 0.5 - 2 seconds. 
 
In  Manual  Override  mode,  the  lights  will  remain  on  for 
around 5 hours. After 5 hours the lights will turn off and 
the motion sensor will revert to Automatic Operation. 
 
Users  can  also  manually  set the  motion  sensor  back  to 
Automatic Operation by: 1) turning the wall switch off and 
on twice within 3 seconds; or 2) turning off the wall switch 
for at least 10 seconds and then turning it back on. 
 

 

TROUBLESHOOTING

 

Light does not turn on 

 

Confirm that you have made a correct “wiring 
connection”. 

 

Ensure that the load is within normal range. 
Change the load if necessary. 

 

Adjust the LUX control knob by turning it 
counterclockwise. 

Light remains on 

 

Make sure the wiring connection is correct. 

 

Adjust the TIME control knob by turning it 
counterclockwise. 

 

Make sure that the unit is not in Manual Override 
mode. 

Others 

 

The specification of protective shield shall consult 
to local service agent. 

 

SPECIFICATIONS

 

Power Requirement 

AC 220 - 240V / 50Hz 

Lighting Load 

15W (7.5W x 2) 

Color Temperature (K) 

5000K 

CRI 

>75 

Lumen (lm) 

800lm (400lm x 2) 

L70 Life Span (hours) 

30000 hr 

Detection Angle 

Up to 180° at 2m Height 

Detection Range 

Up to 12m (39.4ft) at 2m 
Height 

Projection Area 

7m

2

 

Sensor Swiveling Angle 

Up to 90° Leftward 
Up to 90° Rightward 
Up to 30° Downward 

Light Adjustable Angle 

Up to 45

Leftward 

Up to 45° Rightward   
Up to 37.5° Downward 

Mounting Height 

Recommended 2.5m (8.2ft) 
Wall Mount   

Time Adjustment 

5 seconds - 12 minutes 

Lux Adjustment 

30 - 200 Lux 

Operation Mode 

Off/Auto/Manual override 

Warm Up Time 

About 60 seconds 

Working Temperature 

-20

°

C - +40

°

Dimension 

201 x 185 x 167(mm) 

Weight 

796

±

10g 

Protection Class 

Class II 

Protection Degree 

IP44 

Safety 

CE 

*Specifications are subject to change without notice. 

 

A501112090R 

                                                 

 

 
 

 
 
 

Warning: 

Do  not  dispose  of  electrical  appliances  as  unsorted 
municipal waste, use separate collection facilities.   
 
Contact your local government for information regarding 
the collection systems available. 
 
If  electrical  appliances  are  disposed  of  in  landfills  or 
dumps,  hazardous  substances  can  leak  into  the 
groundwater and get into the food chain, damaging your 
health and well-being. 
 

 

Содержание EH313L

Страница 1: ...t can be installed vertically not horizontally as shown in the below drawing FIGURE 1 Wall Mount Recommended FIGURE 1 IMPORTANT Installation must be performed by skilled technicians who are informed about the standards and technical requirements of the appliance and its proper installation Check your local codes as they apply to your situation If the house wiring is of aluminum consult with an ele...

Страница 2: ...mine the proper location to mount the light Use the wall box as a template to mark the fixing holes on the wall Drill the holes and insert the plastic wall plugs supplied Fix the wall box using two screws provided FIGURE 5 m 5 3 8 m FIGURE 5 6 Strip approximately 6 8mm insulating part of the wires from the power cord 7 Connect the BROWN wire Live wire to the terminal block L mark Connect the BLUE ...

Страница 3: ...been detected Turn the TIME control knob clockwise to increase up to 12 minutes the period the lights stay on or counter clockwise to decrease down to 5 seconds the time delay FIGURE 9 Time 5S 12min Time 5S 12min FIGURE 9 3 LUX ADJUSTMENT The LUX control knob determines at which ambient Lux level the lights will turn on when the sensor is in Automatic Operation mode The adjustable Lux range is bet...

Страница 4: ...t in Manual Override mode Others The specification of protective shield shall consult to local service agent SPECIFICATIONS Power Requirement AC 220 240V 50Hz Lighting Load 15W 7 5W x 2 Color Temperature K 5000K CRI 75 Lumen lm 800lm 400lm x 2 L70 Life Span hours 30000 hr Detection Angle Up to 180 at 2m Height Detection Range Up to 12m 39 4ft at 2m Height Projection Area 7m 2 Sensor Swiveling Angl...

Отзывы: