4-8
Remote reception is insensitive or fails.
No
Remote reception is
insensitive or fails.
Check if the remote
control works properly.
Check battery
Check R66
ǃ
C68
Use an oscilloscope to check if
there is output waveform from
the first pin IR of the remote
censor after pressing button on
the remote control.
REM1(PIN 3 - RC waveform
)
Check if there is IR signal
on pin 106 of U12
Check if the power supply
voltage to the remote
censor is normal
Go
No
No
No
Yes
Yes
Yes
Correct connection
Yes
Change U1
IR waveform
Trouble shooting chart
Содержание DVP 1013
Страница 21: ...6 2 6 2 Front Board Print Layout Bottom Side for DVP1013 37 ...
Страница 23: ...6 4 6 4 Power Board Print Layout Bottom Side for DVP1013 37 ...
Страница 28: ...Main Board Print Layout Top Side 6 9 6 9 for DVP1013 37 ...
Страница 29: ...6 10 6 10 Main Board Print Layout Bottom Side for DVP1013 37 ...
Страница 32: ...REVISION LIST Version 1 0 Initial release 8 1 ...