33
W2300
DDC Instructions
Loading DDC data from monitor
1.
Click
icon on the tools bar to bring up the Configuration
Setup windows as Fig.6
2.
Select the DDC2B as the communication channel.
3.
Enable Factory memory data write function and fill in page address
F0 to the block.
4.
Disable Software DDC function.
5.
Click
button to confirm your selection.
Note: The Factory memory data write function will allow EDID30 to
rewrite serial numbers both Analog DDC IC and main EEPROM
to make sure both S/N are exactly the same. You may confirm the
function by checking the S/N at Product information of the OSD
menu after restarting the monitor.
4. Click
button. The main menu appears (as shown on Fig. 5).
Note:
If the connection is improper, you will see the following error
message before entering the main menu. Meanwhile, the
(read EDID) function will be disable. At this time, please make
sure all cables are connected correctly and fixedly, and the
6.
Click
icon to read DDC EDID data from monitor. The EDID
codes will display on screen as following. (The EDID codes are
depend on the model.) Meanwhile, The status bar will indicate
00% to 100% when reading.
Fig. 6
3. At the submenu, type the letter of your computer's floppy disk drive
followed by :EDID301 (for example, A:\EDID301.exe,)
as shown in Fig. 4.
Fig. 4
Fig. 5
Command bar
Tools bar
Status bar
Fig. 7
Содержание Dell W2300
Страница 24: ...Wiring Diagram 24 W2300 Go to cover page ...
Страница 64: ...Scaler PCB C B A 1 64 W2300 9 Go to cover page ...
Страница 65: ...Scaler PCB C B A 2 65 9 Go to cover page W2300 ...
Страница 66: ...Audio PCB C B A 66 W2300 9 Go to cover page ...
Страница 67: ...TV Box PCB C B A 67 9 Go to cover page W2300 ...
Страница 68: ...Power Circuit Diagram 68 W2300 9 Go to cover page ...