![Philips Compaq fp5315 Скачать руководство пользователя страница 62](http://html.mh-extra.com/html/philips/compaq-fp5315/compaq-fp5315_service-manual_1545090062.webp)
HP L1502
62
General Product Specification
Go to cover page
CLASS NO.
Al
l
ri
ght
s
s
tr
ic
tl
y
reser
ved
.
R
epr
oduct
ion
or
is
s
u
e
to
th
ir
d
p
a
rti
e
s
in
a
n
y
fo
rm
w
h
a
te
v
e
r
is
n
o
t
p
e
rm
it
te
d
wi
thout
wr
it
te
n
a
ut
hor
it
y
,
fr
o
m
th
e
p
ro
p
ri
e
to
rs
.
.
NAME
2838 100 05424
TY
CHECK
SUPERS.
DATE
Property of
PHILIPS ELECTRONICS INDUSTRIES (TAIWAN) LTD.-C.E.
10
A4
2003-08-11
HP Wu
15”TFT XGA LCD CMTR
TYPE
: AJ6S40/02
BRAND : HP (L1502)
2003-08-11
8639 000 14754
15
590
18
7.3
HP Monitor Test Summary
7.3.1
Transportation tests
Swept-sine vibration, transportation profile random vibration, and drop tests shall be
performed sequentially on each sample. Packaging or test unit may not be changed at
any point in the test. and a minimum of 3 units must be tests.
Standard
HP Drawing No. 109291
Singal
Sequence
5-150 Hz, 0.5 G
container
30 min. Dwell at lowest natural freq. Each axis, 3 axes.
resonance
Test
Electrical function ok
Result
Mechanical function ok
No serious damage on set appearance
Frist 0.5 Grms, Truck spectrum,
Random
Sequence
Then followed 1.0 Grms Air spectrum
Vibiration
30 Min @ each axis/profile, total 3 axes
Test
Electrical function ok
Result
Mechanical function ok
No serious damage on set appearance
Height
91.4 cm
Sequence
2 corners
remark:filter is use 200 hz
Drop
2 edges
Test
6 faces
Electrical function ok
Test
Mechanical function ok
Result
No serious damage on set appearance
(Room temp./-10 degreeC, humidity 70 %)
8.
Environmental characteristics
8.1
Environmental Requirements
8.1.1
Temperature Ranges
Operating Temperature (Independent of altitude) ............................................................. 5 to 35 degreeC.
Non-Operating Temperature (Independent of altitude)................................................... -20 to 60 degreeC.
8.1.2
Humidity
Operating (non-condensing)......................................................................................................20% to 80%
Non-Operating (38.7 degreeC maximum wet bulb temperature)................................................ 5% to 90%
8.1.3
Altitude
Operating ........................................................ 0 to 12,000 feet [3,658 m]. Equivalent to 14.7 to 10.1 psia.
Non-Operating................................................. 0 to 40,000 feet [12,192 m]. Equivalent to 14.7 to 4.4 psia.
9.
Reliability
9.1
Mean Time between Failure
The demonstrated MTBF shall be 80,000 hours excluding the backlight.
The backlight shall have minimum 30k hour life (50% brightness).
10.
Quality assurance requirements
10.1
Lot Acceptance
According to MIL-STD-105D
Control II level
AQL : 0% (critical ); 0.65% (major); 1.5% (minor)
(Please also refer to annual quality agreement)
Содержание Compaq fp5315
Страница 11: ...HP L1502 11 Go to cover page Wiring Diagram ...
Страница 40: ...40 9 Go to cover page HP L1502 AI 0021CSPEC Power Diagram ...
Страница 41: ...41 9 Go to cover page HP L1502 AI 0021CSPEC Power Diagram ...
Страница 42: ...42 9 Go to cover page HP L1502 Power board P C B Layout ...
Страница 43: ...43 9 Go to cover page Power board P C B Layout HP L1502 ...
Страница 44: ...44 9 Go to cover page Scaler board and P C B Layout HP L1502 ...