Service Modes, Error Codes, and Fault Finding
5.
5.8.10 SSB Replacement
Follow the instructions in the flowchart in case you have to
exchange the SSB. See figure “SSB replacement flowchart”.
Figure 5-14 SSB replacement flowchart
START
Activate SAM and save the TV settings
via “Upload to USB”
Set is still
operating?
Yes
- Replace SSB board by a Service SSB.
- Make the SSB fit mechanically to the set.
Start-up set
Set behaviour?
Activate SAM and reload settings
via “Download from USB”
Saved settings
on USB stick?
Program “Display Option” code via 062598
MENU, followed by 3 digits code (this code
can be found on a sticker inside the set or in
the Service Manual)
Check and perform alignments in SAM
according to the Service Manual
If set is starting-up in Factory mode “F”, push
the “Volume minus” button on the local
keyboard for 5 seconds and restart the set
Connect ComPair, load JETT software and
program set type- and serial number
END
Yes
- Program Display Option code via
062598 MENU
followed by the 3 digit code
(see sticker inside set or in the Service Manual)
- Or program “Display Option” code in SAM via “
062596 i+”, Options, Display, Screen
After entering “Display Option” code, set is
going to Standby (= validation of code)
Restart the set
In case of settings reloaded from USB, the set type- and
set serial number are automatically stored when entering
display options.
No
- Check if correct “Display Option” code is programmed.
- Verify “Option Codes” according sticker inside the set.
- Default settings for White drive ...see Service Manual
Method 1; In some sets it is possible to
program “Display Option” code before set is
going into protection.
Method 2; First bring set in SDM and
program “Display Option” code.
Method 3; Bring the PDP power supply in
stand-alone mode and program the “Display
Option” code.
No
Set is starting up & display is OK
Check latest software on Service website.
Update main and Standby software via USB
3122 785 0098
2
05-FEB-2007
If necessary, adapt the connector plate and/or
the shielding to make the assy fit
mechanically.
Set is starting up but no display
Set goes into protection
Activate SDM via shorting the Service pins on
the SSB
Check changes in CSM
Upgrade main TV SW to the latest version via
USB stick (#)
(#) Some new “Display Option” codes are not recognised
by SSB’s with old(er) SW, resulting in “no display”.
Therefore it is advised to
ALWAYS
update the
main
TV
SW (autorun.upg) via a USB stick to the latest version,
before
setting the “Display Option” code.
Instruction note SSB replacement
H_16771_007.eps
130707
Содержание Cineos 32PFL9432/98
Страница 16: ...Mechanical Instructions EN 16 Q528 1A LA 4 Figure 4 23 Central Sub frame H_16770_097 eps 130707 ...
Страница 48: ...Service Modes Error Codes and Fault Finding EN 48 Q528 1A LA 5 Personal Notes E_06532_012 eps 131004 ...
Страница 148: ...148 Q528 1A LA 7 Circuit Diagrams and PWB Layouts Layout Small Signal Part 1 Top Side Part 1 H_1 ...
Страница 149: ...Circuit Diagrams and PWB Layouts 149 Q528 1A LA 7 Layout Small Signal Part 2 Top Side Part 2 H_16790_047 20 ...
Страница 151: ...Circuit Diagrams and PWB Layouts 151 Q528 1A LA 7 Layout Small Signal Part 1 Bottom Side Part 1 H_1679 ...
Страница 152: ...152 Q528 1A LA 7 Circuit Diagrams and PWB Layouts Layout Small Signal Part 2 Bottom Side Part 2 H_16790_048b eps 200807 ...