ASSEMBLY TIPS + TEST CRITERIA AND CO POSSIBLE COMPLAINTS

ASSEMBLY TIPS

-  Adjusting knob (11) ;
  Before assembling the adjusting 
  knob (11), set the cam of the 
  adjusting unit 10 to the indicated 
 position.

-  Adjusting the hand-strap

- Spring: Before replacing

TEST CRITERIA AND CONTROLS

  

Voltage 

Ampere

Total product 

13.0 V 

380 mA ± 10 %

Adapter: Primary 

voltage 

220-240 

V

 

Secondary voltage 

13.0 V 

400 mA

 

 

if < 12.5 V adapter is defective

Pump 

 

13.0 V 

180 mA ± 10%

Motor rollers 

13.0 V 

180 mA ± 10 %

N.B.

-  To avoid dust from getting into the pump, the suction 
  opening has been closed with a plastic cap. Remove the 
  plastic cap before assembling.

-  After the product has been repaired, it should 
  function properly and has to meet the safety 
  requirements as laid down and offi cially established 
  at this moment.
 

POSSIBLE COMPLAINTS

Status 

Failure Cause

1. Switch in “OFF” position 

Pump functions 

ON/OFF switch defective

2.  Switch set to level 1 

Pump doesn’t function 

Adapter defective

 

 

 

ON/OFF switch defective

 

 

 

Internal wiring broken

  

 

Defective 

PCB

 

 

 

Motor pump defective

3.  Switch set to level 1-5 and 

LED burns 

Filter is clogged

 

product not placed on the skin 

 

Electronic switch defective

  

 

Defective 

PCB 

4.  Switch set to level 1-5 and 

Product doesn’t function 

Electronic switch defective

 

product properly placed 

 

Defective PCB

 

 

 

Sleeves got loose

 

 

 

Vacuum stop defective

 

 

 

Gearing motor defective

 

 

 

Pump clogged - fi lter missing

 

 

 

Internal wiring broken

To check, if the product functions properly. 

- Remove sieve (13).

- Set the switch to level 1. 

  The rollers should rotate continuously and the LED doesn’t burn.

- Cover the suction opening with the thumb. 

  The LED lights up.

- Press the vacuum stop-buttons. 

  The LED goes out and the rollers stop rotating.

1

2

3

4

5

0

2

L

M

S

3

1

2

1

4

2 mm

Содержание Cellesse Sense Active HP 5233

Страница 1: ...help to reduce or prevent the unsightly appearance of cellulite Cellulite is the increased visibility of lumpy fat deposits through the surface of the skin A common used description is orange peel skin because of its unique pitted lumpy appearance Cellulite should not be confused with cellulitis which is a medical term linked to bacterial infection of the skin Cellulite can be reduced with the hel...

Страница 2: ...liance in water or rinse it For the best results clean the appliance after every treatment session with a moist cloth and if necessary a drop of washing up liquid Make sure the filter does not get damp Do not use alcohol acetone benzine abrasives scourers etc to clean the appliance Cleaning the rollers To clean the rollers select Level 1 Wipe the rollers clean with a damp cloth Cleaning the hand s...

Страница 3: ...EXPLODED VIEW DAP1699 3 4 7 103 104 14 12 13 16 A D B I E F 101 102 1 2 9 17 A B H C G A C B H G F D I E 106 105 105 21 8 5 20 19 10 18 11 C D 6 D x l Screws C and D 2x 3 x 9 ...

Страница 4: ...03 035 75010 18 rattle spring 4822 492 32876 19 power jack 4822 265 11618 20 Led green 4822 130 83081 21 adapter EURO 220 240V 4822 219 10056 adapter UK 220 240V 4822 219 10057 adapter JPN 100V 4822 219 10059 adapter Korea 220V 4822 219 10167 adapter Australia 240V 4822 219 10174 adapter Brazil 115 220V 4822 219 10171 adapter China 220V 4822 219 10338 adapter universal 110 127V 4203 035 75060 22 t...

Страница 5: ... this moment POSSIBLE COMPLAINTS Status Failure Cause 1 Switch in OFF position Pump functions ON OFF switch defective 2 Switch set to level 1 Pump doesn t function Adapter defective ON OFF switch defective Internal wiring broken Defective PCB Motor pump defective 3 Switch set to level 1 5 and LED burns Filter is clogged product not placed on the skin Electronic switch defective Defective PCB 4 Swi...

Отзывы: