background image

Lightolier is a Philips group brand

Job Information 

Type:

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2011 Philips Group • C0711

Calculite

®

 CFL Lensed Wall Washer

 8046

Page 2 of 2 

6" Aperture Triple Tube Vertical Lamp

2' From Wall-3' On Center

1

27

16

27

2

36

27

36

3

26

25

26

4

19

19

19

5

14

14

14

6

11

11

11

7

9

9

9

8

7

7

7

9

6

6

6

2' From Wall-2' On Center

1

33

30

33

2

48

46

48

3

38

38

38

4

28

28

28

5

20

20

20

6

15

15

15

7

12

12

12

8

10

10

10

9

8

8

8

2' From Wall-2' On Center

1

24

22

24

2

31

31

31

3

28

28

28

4

22

22

22

5

17

17

17

6

13

13

13

7

10

11

10

8

9

9

9

9

7

7

7

3' From Wall-4' On Center

1

6

4

6

2

11

9

11

3

11

10

11

4

11

10

11

5

9

9

9

6

8

8

8

7

7

7

7

8

6

6

6

9

6

6

6

3' From Wall-3' On Center

1

7

6

7

2

13

12

13

3

14

14

14

4

14

14

14

5

12

12

12

6

10

11

10

7

9

9

9

8

8

8

8

9

7

7

7

Lighting  Data
Footcandles On Wall: Multiple 26w Units

3"

2"

20 f.c.
19 f.c.

3'

2' From Wall-3' On Center

1

19

12

19

2

23

19

23

3

20

19

20

4

15

15

15

5

12

12

12

6

9

9

9

7

8

8

8

8

6

6

6

9

6

6

6

Footcandles On Wall: Multiple 32w Units

3' From Wall-3' On Center

1

9

8

9

2

19

18

19

3

22

21

22

4

19

19

19

5

16

16

16

6

13

13

13

7

11

11

11

8

9

9

9

9

8

8

8

3' From Wall-4' On Center

1

8

5

8

2

16

12

16

3

17

15

17

4

15

14

15

5

12

12

12

6

10

10

10

7

8

8

8

8

7

7

7

9

6

6

6

3"

2"

25 f.c.

26 f.c.

3'

EXAMPLE: With multiple clear reflector units located 2' from wall and

spaced 3' on center, the illumination on the wall 3' down from ceiling
will be 19 f.c. beneath units and 20 f.c. between units.

EXAMPLE: With multiple clear reflector units located 2' from wall and

spaced 3' on center, the illumination on the wall 3' down from ceiling
will be 26 f.c. beneath units and 25 f.c. between units.

Footcandle values are averaged and rounded off and based on minimum of five units.

Distance 

From 

Ceiling 

in 

Feet

Distance 

From 

Ceiling 

in 

Feet

Distance 

From 

Ceiling 

in 

Feet

Distance 

From 

Ceiling 

in 

Feet

Distance 

From 

Ceiling 

in 

Feet

Distance 

From 

Ceiling 

in 

Feet

Distance 

From 

Ceiling 

in 

Feet

Distance 

From 

Ceiling 

in 

Feet

Отзывы: