background image

READ AND FOLLOW ALL SAFETY INSTRUCTIONS

! IMPORTANT SAFEGUARDS !

WHEN USING ELECTRICAL EQUIPMENT, BASIC

SAFETY PRECAUTIONS SHOULD ALWAYS BE 

FOLLOWED, INCLUDING THE FOLLOWING:

SAVE THESE INSTRUCTIONS

THIS PRODUCT CONTAINS A RECHARGEABLE NICKEL-CADMIUM BATTERY.  

THE BATTERY MUST BE RECYCLED OR DISPOSED OF PROPERLY.

© Philips Emergency Lighting

A Division of Philips Electronics North America Corporation

236 Mt. Pleasant Rd. • Collierville, TN USA 38017-2752 • Tech Support 888-263-4638 • Fax 901-854-1630 • www.philips.com/bodine

70094021

EMERGENCY LIGHTING EQUIPMENT

Installation Instructions for TYPE 2

  1.  To prevent high voltage from being present on red, yellow & yellow/black output leads prior to  
    installation, inverter connector must be open. Do not join inverter connector until installation is  
    complete and AC power is supplied to the emergency ballast.
  2.  This product is for use with one 13 W through 42 W (4-pin) compact fluorescent lamp without integral  
    starter.
  3.  Make sure all connections are in accordance with the National Electrical Code and any local regulations.
  4.  To reduce the risk of electric shock, disconnect both normal and emergency power supplies and  

 

    inverter connector of the emergency ballast before servicing.
  5.  This emergency ballast is for factory or field installation.
  6.  This product is suitable for damp locations where the ambient ballast temperature is 0°C minimum, +50°C
    maximum. Product is not suitable for heated air outlets and wet or hazardous locations.
  7.  An unswitched AC power source is required (120 or 277 VAC, 60 Hz).
  8.  Do not install near gas or electric heaters.
  9.  Do not attempt to service the battery. A sealed, no-maintenance battery is used that is not field 
    replaceable. Contact the manufacturer for information on service.
 10.  The use of accessory equipment not recommended by the manufacturer may cause an unsafe  
    condition.
 11.  Do not use this product for other than intended use.
 12.  Servicing should be performed by qualified service personnel.

B94G

03/21/11

Ni - Cd

Содержание Bodine B94G Type 2

Страница 1: ...2 W 4 pin compact fluorescent lamp without integral starter 3 Make sure all connections are in accordance with the National Electrical Code and any local regulations 4 To reduce the risk of electric shock disconnect both normal and emergency power supplies and inverter connector of the emergency ballast before servicing 5 This emergency ballast is for factory or field installation 6 This product i...

Страница 2: ... test monitor plate On switched fixtures an additional unswitched hot wire 120 or 277 VAC must be run and connected to the emergency ballast STEP 2 WIRING THE EMERGENCY BALLAST Cut the fixture wires between the lamp holder and AC ballasts and connect the blue and blue white emergency ballast wires to the AC ballast and the yellow and yellow black wires to the lamp holder Connect the LED by matchin...

Страница 3: ...he fixture at 30 day intervals for a minimum of 30 seconds One lamp should operate at reduced illumination 3 Conduct a 90 minute discharge test once a year One lamp should operate at reduced illumination for at least 90 minutes REFER ANY SERVICING INDICATED BY THESE CHECKS TO QUALIFIED PERSONNEL OPERATION MAINTENANCE EMERGENCY BALLAST AND AC BALLAST MUST BE FED FROM THE SAME BRANCH CIRCUIT TYPICAL...

Страница 4: ...SWITCHED HOT INVERTER CONNECTOR RED WHITE AC BALLAST EMERGENCY YELLOW RED YEL BLK COMMON WHITE RED RED WHITE WHT BLK BLUE BLUE BLU WHT BLUE BLACK WHT RED BLACK 120V OR ORANGE 277V CAP UNUSED LEAD VIOLET BROWN BLACK BLACK VIOLET BROWN ITS B A L L A S T E M E R G E N C Y WALL SWITCH UNSWITCHED HOT INVERTER CONNECTOR RED WHITE AC BALLAST EMERGENCY YELLOW YELLOW YELLOW RED YEL BLK COMMON WHITE RED RED...

Отзывы: