background image

FIG CP104.  TWO (2) LAMP INSTANT START BALLAST

FIG CP106.  THREE (3) LAMP INSTANT START BALLAST

FIG CP105.  THREE (3) LAMP RAPID START BALLAST

EMERGENCY BALLAST AND AC BALLAST MUST BE FED FROM THE SAME BRANCH CIRCUIT

TYPICAL SCHEMATICS ONLY.  MAY BE USED WITH OTHER BALLASTS. CONSULT THE FACTORY FOR OTHER WIRING DIAGRAMS.

WIRING DIAGRAMS FOR 1-LAMP EMERGENCY OPERATION

FIG CP121.  FOUR (4) LAMP INSTANT START BALLAST

FIG CP119.  ONE (1) LAMP INSTANT START BALLAST

FIG CP099.  ONE (1) LAMP RAPID START BALLAST

E

M

E

R

G

E

N

C

Y

B

A

L

L

A

S

T

BLACK
WHITE

WHITE

WHT/BLK

COMMON

WALL SWITCH

WHT/RED

RED

WHITE

)
BROWN(-)

(CAP UNUSED LEAD)

BLACK 120V

OR

ORANGE 277V

INVERTER

CONNECTOR

HOT

ITS

BLACK

BLK

BROWN

VIOLET

LAMP

1 LAMP

INSTANT

START

BALLAST

WARNING: Refer to Table 1 before connecting

BLUE

BROWN
BROWN
RED
YELLOW
YEL/BLK
BLU/WHT
BLUE

RED

E

M

E

R

G

E

N

C

Y

B

A

L

L

A

S

T

BLACK
WHITE

WHITE

WHT/BLK

COMMON

WALL SWITCH

WHT/RED

RED

WHITE

)
BROWN(-)

(CAP UNUSED LEAD)

BLACK 120V

OR

ORANGE 277V

INVERTER

CONNECTOR

HOT

ITS

BLACK

BLK

BROWN

VIOLET

LAMP

1 LAMP

RAPID START

BALLAST

WARNING: Refer to Table 1 before connecting

BLUE
BLUE

BROWN
BROWN
RED
YELLOW
YEL/BLK
BLU/WHT
BLUE

RED
RED

E

M

E

R

G

E

N

C

Y

B

A

L

L

A

S

T

BLACK
WHITE

WHITE

WHT/BLK

COMMON

WALL SWITCH

WHT/RED

RED

WHITE

)
BROWN(-)

(CAP UNUSED LEAD)

BLACK 120V

OR

ORANGE 277V

INVERTER

CONNECTOR

HOT

ITS

BLACK

BLK

BROWN

VIOLET

LAMP 1 

LAMP 2

2 LAMP

INSTANT

START

BALLAST

WARNING: Refer to Table 1 before connecting

BLUE

BROWN
BROWN
RED
YELLOW
YEL/BLK
BLU/WHT

BLUE

BLUE

RED

(

)

EMERGENCY

E

M

E

R

G

E

N

C

Y

B

A

L

L

A

S

T

BLACK
WHITE

WHITE

WHT/BLK

COMMON

WALL SWITCH

WHT/RED

RED

WHITE

)
BROWN(-)

(CAP UNUSED LEAD)

BLACK 120V

OR

ORANGE 277V

INVERTER

CONNECTOR

HOT

ITS

BLACK

BLK

BROWN

VIOLET

LAMP 1 

LAMP 2

2 LAMP

RAPID START

BALLAST

WARNING: Refer to Table 1 before connecting

BLUE
BLUE

BROWN
BROWN
RED
YELLOW
YEL/BLK
BLU/WHT
BLUE

RED
RED

YELLOW
YELLOW

(

)

EMERGENCY

E

M

E
R
G
E
N
C
Y

B
A
L
L
A
S
T

BLACK
WHITE

WHITE

WHT/BLK

COMMON

WALL SWITCH

WHT/RED

RED

WHITE

)
BROWN(-)

(CAP UNUSED LEAD)

BLACK 120V

OR

ORANGE 277V

INVERTER

CONNECTOR

HOT

ITS

BLACK

BLK

BROWN

VIOLET

3 LAMP

INSTANT

START

BALLAST

WARNING: Refer to Table 1 before connecting

BLUE

BROWN
BROWN
RED
YELLOW
YEL/BLK
BLU/WHT

BLUE

BLUE

BLUE

RED

(

)

EMERGENCY

LAMP 1 

LAMP 2

LAMP 3

E

M

E

R

G

E

N

C

Y

B

A

L

L

A

S

T

BLACK
WHITE

WHITE

WHT/BLK

COMMON

WALL SWITCH

WHT/RED

RED

WHITE

)
BROWN(-)

(CAP UNUSED LEAD)

BLACK 120V

OR

ORANGE 277V

INVERTER

CONNECTOR

HOT

ITS

BLACK

BLK

BROWN

VIOLET

(

)

LAMP 1 

EMERGENCY

LAMP 2

LAMP 3

3 LAMP

RAPID START

BALLAST

BLUE
BLUE

BROWN
BROWN
RED
YELLOW
YEL/BLK
BLU/WHT
BLUE

YELLOW
YELLOW

BLU/WHT

BLU/WHT

RED
RED

WARNING: Refer to Table 1 before connecting

E

M

E

R

G

E

N

C

Y

B

A

L

L

A

S

T

BLACK
WHITE

WHITE

WHT/BLK

COMMON

WALL SWITCH

WHT/RED

RED

WHITE

)
BROWN(-)

(CAP UNUSED LEAD)

BLACK 120V

OR

ORANGE 277V

INVERTER

CONNECTOR

HOT

ITS

BLACK

BLK

BROWN

VIOLET

(

)

EMERGENCY

LAMP 1 

LAMP 2

LAMP 3

LAMP 4

4 LAMP

INSTANT

START

BALLAST

WARNING: Refer to Table 1 before connecting

BLUE

BROWN
BROWN
RED
YELLOW
YEL/BLK
BLU/WHT
BLUE

BLUE

YELLOW

RED

YELLOW
RED

FIG CP120.  FOUR (4) LAMP RAPID START BALLAST

FIG CP134.  ONE (1) LAMP COMPACT RAPID START BALLAST

FIG CP135.  TWO (2) LAMP COMPACT RAPID START BALLAST

E

M

E

R

G

E

N

C

Y

B

A

L

L

A

S

T

BLACK
WHITE

WHITE

WHT/BLK

COMMON

WALL SWITCH

WHT/RED

RED

WHITE

)
BROWN(-)

(CAP UNUSED LEAD)

BLACK 120V

OR

ORANGE 277V

INVERTER

CONNECTOR

HOT

ITS

BLACK

BLK

BROWN

VIOLET

(

)

LAMP 1 

EMERGENCY

LAMP 2

LAMP 3

LAMP 4

4 LAMP

RAPID START

BALLAST

RED
RED

BROWN
BROWN
RED
YELLOW
YEL/BLK
BLU/WHT
BLUE

BLU/WHT
BLU/WHT

YELLOW

BRN

BRN

BLUE
BLUE

YELLOW

WARNING: Refer to Table 1 before connecting

1 LAMP

RAPID START

BALLAST

BLUE
BLUE

BROWN
BROWN
RED
YELLOW
YEL/BLK
BLU/WHT
BLUE

RED
RED

LAMP 1

WARNING: Refer to Table 1 before connecting

E

M

E

R

G

E

N

C

Y

B

A

L

L

A

S

T

BLACK
WHITE

WHITE

WHT/BLK

COMMON

WALL SWITCH

WHT/RED

RED

WHITE

)
BROWN(-)

(CAP UNUSED LEAD)

BLACK 120V

OR

ORANGE 277V

INVERTER

CONNECTOR

HOT

ITS

BLACK

BLK

BROWN

VIOLET

2 LAMP

RAPID START

BALLAST

BLUE
BLUE

BROWN
BROWN
RED
YELLOW
YEL/BLK
BLU/WHT
BLUE

YELLOW

YELLOW
RED
RED

LAMP 1

LAMP 2

WARNING: Refer to Table 1 before connecting

EMERGENCY

E

M

E

R

G

E

N

C

Y

B

A

L

L

A

S

T

BLACK
WHITE

WHITE

WHT/BLK

COMMON

WALL SWITCH

WHT/RED

RED

WHITE

)
BROWN(-)

(CAP UNUSED LEAD)

BLACK 120V

OR

ORANGE 277V

INVERTER

CONNECTOR

HOT

ITS

BLACK

BLK

BROWN

VIOLET

FIG CP141.  TWO (2) LAMP OSRAM RAPID START BALLAST

E

M

E

R

G

E

N

C

Y

B

A

L

L

A

S

T

BLACK
WHITE

WHITE

WHT/BLK

COMMON

WALL SWITCH

WHT/RED

RED

WHITE

)
BROWN(-)

(CAP UNUSED LEAD)

BLACK 120V

OR

ORANGE 277V

INVERTER

CONNECTOR

HOT

ITS

BLACK

BLK

BROWN

VIOLET

LAMP 1 

LAMP 2

2 LAMP

RAPID START

BALLAST

WARNING: Refer to Table 1 before connecting

RED
RED

BROWN
BROWN
RED
YELLOW
YEL/BLK
BLU/WHT

BLUE

BLUE
BLUE

YELLOW
YELLOW

(

)

EMERGENCY

4

FIG CP124.  TWO (2) LAMP RAPID START STEP DIMMING BALLAST

LAMP (EMERGENCY)

LAMP

BLUE

BLUE

RED

YELLOW

RED
YELLOW
YEL/BLK
BLU/WHT

BLUE

RED

YELLOW

2 LAMP

RAPID
START

STEP

DIMMING

BALLAST

WARNING: Refer to Table 1 before connecting

E

M

E

R

G

E

N

C

Y

B

A

L

L

A

S

T

BLACK

WHITE

BROWN
BROWN

WHITE

WHT/BLK

COMMON

WHT/RED

RED

WHITE

)
BROWN(-)

(CAP UNUSED LEAD)

BLACK 120V

OR

ORANGE 277V

INVERTER

CONNECTOR

HOT

ITS

BLACK

BLK

BROWN

VIOLET

BLACK

S1
S2

FIG CP124.  TWO (2) LAMP RAPID START BALLAST

THE  WHITE/BLACk  LEAD  MUST  CONNECT  TO  THE  WHITE 
LEAD OF THE STEP-DIMMING BALLAST ASSOCIATED WITH 
THE EMERGENCY BALLAST ONLY.  CONNECTIONS TO OTHER 
BALLASTS  OR  FIxTURES  COULD  RESULT  IN  ABNORMAL 
OPERATION AND CAUSE PRODUCT DAMAGE.

Содержание B50LP

Страница 1: ...d start 4 pin long compact fluorescent lamps 3 Make sure all connections are in accordance with the National Electrical Code and any local regulations 4 To reduce the risk of electric shock disconnect both normal and emergency power supplies and inverter connector of the emergency ballast before servicing 5 This emergency ballast is for factory or field installation in either the ballast channel o...

Страница 2: ... on top of fixture 2 UNSWITCHED FIXTURE SWITCHED FIXTURE E M E R G E N C Y A C B A L L A S T B A L L A S T BLACK WHITE WHITE WHT BLK COMMON E M E R G E N C Y A C B A L L A S T B A L L A S T BLACK WHITE WHITE WHT BLK COMMON E M E R G E N C Y A C B A L L A S T B A L L A S T BLACK WHITE WHITE WHT BLK COM WALL SWITCH WHT RED B L K B L K CAP UNUSED LEAD BLACK 120V OR ORANGE 277V HOT E M E R G E N C Y A...

Страница 3: ...t installed in the fixture Select the appropriate wiring diagram on back to connect the emergency ballast to the AC ballast and lamp s Make sure all connec tions are in accordance with the National Electrical Code and any local regulations After installation is complete supply AC power to the emergency ballast and join the inverter connector At this point power should be connected to both the AC b...

Страница 4: ...G Refer to Table 1 before connecting E M E R G E N C Y B A L L A S T BLACK WHITE WHITE WHT BLK COMMON WALL SWITCH WHT RED RED WHITE VIOLET BROWN CAP UNUSED LEAD BLACK 120V OR ORANGE 277V INVERTER CONNECTOR HOT ITS BLACK BLK BROWN VIOLET EMERGENCY LAMP 1 LAMP 2 LAMP 3 LAMP 4 4 LAMP INSTANT START BALLAST WARNING Refer to Table 1 before connecting BLUE BROWN BROWN RED YELLOW YEL BLK BLU WHT BLUE BLUE...

Страница 5: ... BLK BLU WHT BLUE RED RED YELLOW YELLOW LAMP 1 LAMP 2 WARNING Do NOT connect brown connector FIG CP129 FOUR 4 LAMP INSTANT START BALLAST FIG CP128 FOUR 4 LAMP RAPID START BALLAST E M E R G E N C Y B A L L A S T BLACK WHITE WHITE WHT BLK COMMON WALL SWITCH WHT RED RED WHITE VIOLET BROWN CAP UNUSED LEAD BLACK 120V OR ORANGE 277V INVERTER CONNECTOR HOT ITS BLACK BLK BROWN VIOLET LAMP 1 LAMP 2 LAMP 3 ...

Отзывы: