5-1
PL10.4EA
ELECTRICAL ADJUSTMENT INSTRUCTIONS
General Note: “CBA” is abbreviation for
“Circuit Board Assembly.”
Note:
Electrical adjustments are required after
replacing circuit components and certain
mechanical parts. It is important to perform
these adjustments only after all repairs and
replacements have been completed.
Also, do not attempt these adjustments unless
the proper equipment is available.
Test Equipment Required
1. NTSC Pattern Generator (Color Bar W/White
Window, Red Color, Dot Pattern, Gray Scale,
Monoscope, Multi-Burst)
2. Remote control unit
3. Color Analyzer
How to set up the service mode:
Service mode:
1. Turn the power on.
2. Press [0], [6], [2], [5], [9], [6] and [INFO] buttons on
the remote control unit in this order. The following
screen appears.
1. Purity Check Mode
This mode cycles through full-screen displays of red,
green, blue, and white to check for non-active pixels.
1. Enter the Service mode.
2. Each time pressing [7] button on the remote
control unit, the display changes as follows.
3. To cancel or to exit from the Purity Check Mode,
press [PREV. CH] button.
"*" differs depending on the models.
[current]
File code :
Total checksum :
Panel-Option code :
***-***-***-*
Push"0"key
**-***-***
Press "POWER" key to exit.
[FRC]
SoftwareID :
Checksum :
BootID :
Tuner :
Safety :
EDID :
Lightsensor : **
********-*****
****
***
*****
Safety_Non
Push"0"key
[7] button
Note:
When entering this mode, the default setting is White mode.
Purity Check Mode
[7] button
Red mode
Green mode
Blue mode
Black mode
[7] button
White mode
[7] button
[7] button
White 20% mode
[7] button
Содержание 40PFL5505D/F7
Страница 14: ...4 2 PL10 4DC 2 Rear Cabinet S 1 1 Stand Assembly S 2 S 2 S 2 S 2 S 2 S 2 S 2 S 3 Fig D1 ...
Страница 42: ...10 14 PL10 4SCD12 Digital Main 12 Schematic Diagram ...
Страница 43: ...10 15 PL10 4SCD13 Digital Main 13 Schematic Diagram ...
Страница 45: ...10 17 PL10 4SCF Function Schematic Diagram ...
Страница 46: ...10 18 PL10 4SCIR IR Sensor Schematic Diagram ...