![Philips 40PFH6510/88 Скачать руководство пользователя страница 27](http://html.mh-extra.com/html/philips/40pfh6510-88/40pfh6510-88_service-manual_309666027.webp)
Mechanical Instructions
4.
4.5.3
AmbiLight Panel
Refer to
for details.
1. Gently release the clamps and unplug the connectors [5]
that secure the ambilight panels. Release the clips from the
FFC connector that connect with the Keyboard control
panel [4].
2. Lift the AmbiLight panel from the rear cover. Make sure that
wires and flat foils are not damaged while lifting the
Ambilight panel from the rear cover.
Figure 4-31 Ambilight and Keyboard removal
4.5.4
Keyboard Control Unit
Refer to
for details.
1. Release the connector [2] from the SSB Board, then
release the connector [3] from the Ambilight panel.
Caution:
be careful, as these are very fragile connectors!
2. Remove all the fixation screws from the keyboard control
panel [1] and take it out from the Back cover.
When defective, replace the whole unit.
4.5.5
Small Signal Board (SSB)
Refer to
for details.
Caution:
it is mandatory to remount all different screws at their
original position during re-assembly. Failure to do so may result
in damaging the SSB.
1. Release the clips from the LVDS connector that connect
with the SSB [1].
Caution:
be careful, as these are very fragile connectors!
Unplug the cable/flat foils connector.
2. Unplug all other connectors [2].
3. Remove all the fixation screws from the SSB [3].
4. Take out the SSB with I/O bracket.
5. The SSB can now be shifted away from side connector
cover, then lifted and taken out of the I/O bracket. Refer to
for details.
Figure 4-32 SSB removal
19883_104.eps
3
2
4
5
1
1
5
19883_105.eps
2
1
3
3
3
3
2