10-23
BA01F2F01031
Inverter CBA, Function CBA, IR Sensor CBA & Junction CBA Bottom View
NOTE:
The voltage for parts in hot circuit is measured using
hot GND as a common terminal.
Because a hot chassis ground is present in the power supply
circuit, an isolation transformer must be used when repairing.
Also, in order to have the ability to increase the input slowly,
when troubleshooting this type of power supply circuit,
a variable isolation transformer is required.
Function CBA
Not Used
IR Sensor CBA
Junction CBA [TYPE A, TYPE B]
Not Used
Inverter CBA
Содержание 32PFL3505D/F7
Страница 14: ...4 2 PL10 3DC 2 Rear Assembly S 1 1 Stand Assembly S 2 S 2 S 2 S 3 S 2 S 4 S 3 Fig D1 ...
Страница 19: ...4 7 PL10 3 A01FU DC 2 Rear Assembly S 1 1 Stand Assembly S 2 S 2 S 2 S 3 S 2 S 4 S 3 Fig D1 ...
Страница 58: ...10 4 PL10 3SCP2 Power Supply 2 Schematic Diagram ...
Страница 59: ...10 5 PL10 3SCP3 Power Supply 3 Jack Schematic Diagram ...
Страница 60: ...10 6 PL10 3SCP4 Power Supply 4 Schematic Diagram ...
Страница 62: ...10 8 PL10 3SCF Function Schematic Diagram ...
Страница 63: ...10 9 PL10 3SCIR IR Sensor Junction Schematic Diagram ...