43
Meridian 5
Reset the factory setting
1.
Power on the monitor and open the user menu.
2.
Do factory reset: Setup – Reset – Yes.
3.
Factory reset will turn off “Burn in” mode which screen color switches among red, green, blue and black.
11.5 Troubleshooting:
“CheckSum Comparing Fail!” error.
Method: Tick the “Send MX2060 CMD” at Option item.
When can’t upgrade, please retry below several ways to upgrade.
(1) When the tool appears erase error, you can change another version tool to try.
(2) The program must be in the monitor standby state, while the fail communication with monitor might result the
monitor power off. In this situation, you may AC off the monitor for a while and then AC on to retry. Maybe the
defect will be cured.
(3) Change ISP JIG or cable.
(4) Change PC.
Содержание 274E5QDAB/00(AD)
Страница 5: ... 5 Meridian 5 1 Monitor Specifications ...
Страница 6: ...Meridian 5 6 ...
Страница 9: ... 9 Meridian 5 3 Operating Instructions ...
Страница 10: ...Meridian 5 10 ...
Страница 13: ... 13 Meridian 5 4 2 Philips Flat Panel Monitors Pixel ...
Страница 14: ...Meridian 5 14 ...
Страница 25: ...25 Meridian 5 8 Scaler Board Overview Flash ROM Scaler IC VGA EEPROM FFC Connector DVI EEPROM HDMI EEPROM ...
Страница 30: ... 30 Meridian 5 The bezel The bezel The panel The panel ...
Страница 36: ... 36 Meridian 5 Click Finish to complete the USB serial port driver installation ...
Страница 38: ... 38 Meridian 5 2 Connection ...
Страница 40: ... 40 Meridian 5 ...
Страница 59: ...59 Meridian 5 14 Monitor Exploded View ...
Страница 61: ...61 Meridian 3 Service Kit Description Part No Picture ISP JIG 715GT089 B C EDID JIG 715GT034 B ...