(1) Input signal : As defined in 3.3, 1440*900, non-interlaced mode (1440*900@60Hz 146.25MHz), signal,
sources must have 75 ohm output impedance.
(2) Luminance setting : controls to be set to 300 nits with full screen 100 % duty cycle white signal
(3) Warm up: more than 30 minutes after power on with signal supplied.
(4) Ambient light: 400 -- 600 lux.
(5) Ambient temperature: 20 ± 5
°
C
7.3 Test equipment
Personal computer with Windows 98/2000/XP
Luminance meter Minolta CA110
Videogenerator: Chroma 2000, 2135, 2250 or equivalent
Colour analyzer: Minolta or Chroma
10 times magnifier
Ruler / Template
7.4 Video Generator test sequence
Will be defined by TVI or its subcontracted quality providers.
7.5
HV separate sync, composite sync,
7.6
7.7 Protection circuit
The monitor will not be damaged by:
missing vertical or horizontal sync pulse
7.8
DDC
The monitor can support DDC 2 B and DDC-CI according to the latest VESA standard.
7.8.1 DDC
1
User visible strings on .inf file
Philips 190VW8 (19inch WIDE LCD MONITOR 190VW8)
2
3
Product ID, "xxxx" 4 codes
MSB(byte 12): 08
LSB (byte 11): 60
4 maximum
resolution
1440x900
5
Horizontal Frequency Range
30~83 KHz
6
Vertical Frequency Range
55~76Hz
7
Monitor Name (13 characteries max.) Philips 190VW
64
190VW8 LCD