65
170S5 LCD
Satety Test Requirements
All units that are returned for service or repair must pass the
original manufactures safety tests. Safety testing requires both
and
testing.
Hipot
Ground Continuity
HI-POT TEST INSTRUCTION
1.Application requirements
2.
1.1 All mains operated products must pass the Hi-Pot test as
described in this instruction.
1.2 This test must be performed again after the covers have
been refitted following the repair, inspection or modification
of the product.
2.1 Connecting conditions
2.1.1 The test specified must be applied between the parallel-
blade plug of the mainscord and all accessible metal
parts of the product.
2.1.2 Before carrying out the test, reliable conductive
connections must be ensured and thereafter be
maintained throughout the test period.
2.1.3 The mains switch(es) must be in the "ON" position.
2.2 Test Requirements
All products should be HiPot and Ground Continuity tested as
follows:
Test
2820VDC
1700VDC
Test current:
voltage
(2000VAC)
(1200VAC)
25A,AC
Test time:
Test time 3 seconds
1 second
3 seconds(min.)
(min.)
Resistance
required:
Trip
set at 100 uA
5 mA
<=0.09+Rohm,
current
for Max.
R is the
(Tester)
limitation; set
resistance of
at 0.1 uA for
the mains cord.
Min. Limitation
Ramp
set at 2
time
seconds
(Tester)
Test method
Condition
HiPot Test for
HiPot Test for
Ground Continuity
products where
products where
Test requirement
the mains input
the mains input is
range is Full
110V AC(USA
range(or 220V
type)
AC)
2.2.1 The minimum test duration for Quality Control Inspector
must be 1 minute.
2.2.2 The test voltage must be maintained within the specified
v 5%.
2.2.3 There must be no breakdown during the test.
2.2.4 The grounding blade or pin of mains plug must be
conducted with accessible metal parts.
3.
Equipments and Connection
3.1. Equipments
For example :
- ChenHwa 9032 PROGRAMMABLE AUTO SAFETY
TESTER
- ChenHwa 510B Digital Grounding Continuity Tester
- ChenHwa 901 (AC Hi-pot test), 902 (AC, DC Hi-pot test)
Withstanding Tester
3.2. Connection
4.
Recording
Hipot and Ground Continuity testing records have to be kept
for a period of 10 years.
* Turn on the power switch of monitor before Hipot and
Ground Continuity testing.
Connect the "video cable"
or "grounding screw"
to the CLIP on your tester.
Video cable
(Rear view of monitor)
Connect the power cord
to the monitor.
Grounding screw
Power outlet
(ChenHwa 9032 tester)
Clip
Clip
Go to cover page
Содержание 170S5FG/00
Страница 11: ...11 170S5 LCD Go to cover page Wiring Message ...
Страница 28: ...DSUB Diagram Go to cover page 170S5 LCD 28 ...
Страница 29: ...Micro Diagram 29 170S5 LCD Go to cover page ...
Страница 30: ...Scaler Diagram Go to cover page 170S5 LCD 30 ...
Страница 31: ...Connector Diagram 31 170S5 LCD Go to cover page ...
Страница 32: ...Scaler Board C B A 1 Go to cover page 170S5 LCD 32 ...
Страница 33: ...Scaler Board C B A 2 33 170S5 LCD Go to cover page ...
Страница 34: ...Control Board Diagram Go to cover page 170S5 LCD 34 Control Board C B A ...
Страница 35: ...35 170S5 LCD Go to cover page ...
Страница 36: ...Go to cover page 170S5 LCD 36 ...
Страница 37: ...37 170S5 LCD Go to cover page Power Board C B A 2 Power Board C B A 1 ...
Страница 38: ......