11. Repair Flow Chart
11.1 Main Board
(1). No Power
No power
Press power key and look
if the picture is normal
Please reinsert and make sure
the AC of 100-240 is normal
Reinsert or check the
Adapter/Inverter
section
X401 oscillate waveforms
are normal
Replace U201
Replace U501
Replace X401
OK
OK
OK
NG
NG
NG
NG
Measure U201 PIN2=3.3V