69
150B LCD
Go to cover page
Forward
Back
14
15" TFT XGA LCD CMTR-150B1C
TYPE
: 150B1C/00
BRAND : PHILIPS
8639 000 10511
00-03-16
Y. L. LIU
00-03-16
18
590
6.0
Environmental characteristics
The following sections define the interference and
susceptibility condition limits that might occur
between external environment and the display device.
6.1
Susceptibility of display to external environment
Operating
- Temperature
: 0 to 40 degree C
- Humidity
: 80% max, no condensation
- Altitude
: 0-3658m
- Air pressure
: 600-1100 mBAR
Storage
- Temperature
: -20 to 60 degree C
- Humidity
: 95% max ( < 40¢J ) ,no condensation
- Altitude
: 0-12192m
- Air pressure
: 300-1100 mBAR
Note: recommend at 0 to 40C, Humidity less than 60 %
6.2
Transportation tests
Standard
Philips UAN-D1400
NSTA
Height
61.0 cm
76.0 cm
1 corner
1 corner
Drop
Sequence
3 faces
3 edge
Test
(-10deg C x 16 hrs)
(room temp) 6 face
electrical function ok
Test
Mechanical function ok
Result
no serious damage on set appearance
(room temp./-10 c, humidity 70 %)
(1) PACKAGING
Sequence
5-200 Hz , 0.73 G , 30 min. for Each axis
(2) OPERATING
Vibration
10-50-10 Hz , 0.35 mm , 30 min. for Each axis
Test
Test
electrical function ok
Result
Mechanical function ok
no serious damage on set appearance
For design evaluation
only
Operating
10 G, 11 msec, 1000 cycles
Bump
temperature :
23 C
Test
humidity
: 60 %
air pressure : 100 kpa
(according to DSD draft standard UAN-D636)
°
°
General Product Specifications (Continued)