62
109P2 GS3 CM25
GENERAL PRODUCT SPECIFICATION
9
Go to cover page
Forward
Back
8639 000 10535
00-08-01
JACK LIN
00-08-01
590
15
31
19" AUTO SCAN CMTR
TYPE
: 109P20/00C-CM25+109P2
BRAND : PHILIPS
3.6
Degaussing
An automatic degaussing circuit is provided and required no intervention.
The degaussing is activated at the time of switch-on and power saving
wake up or switch-on again after switched-off for longer than 30 minutes.
.
Manual degaussing is provided to eliminate any color impurity.
3.7
Requirement for low emission
(1) Electro static potential : < 0.5 KV
(2) Alternating Elec. field
ELF 5 - 2 Khz : 10.0 V/M
VLF 2 - 400 KHz
: 1.0 V/M
(3) Magnetic field
ELF 5 - 2 Khz : 200 nT
VLF 2 - 400 Khz : 25 nT
3.8
Power management
The power consumption and the status indication of the set
with power management function are as follows,
On
Pulse
Pulse
as normal on
Green
Stand-by
No Pulse
Pulse
< 10 W
Yellow
Suspend
Pulse
No Pulse
< 10 W
Yellow
Power off
No Pulse
No Pulse
< 3 W
Amber
Entering from ON state to Power saving state must has 5
- 10 second time delay. It must awake from Suspend
state to On state within 3 seconds.
According to
VESA power saving signalling.
TCO99 power saving requirement
EPA energy star requirement
E2000
STATUS
Horizontal Vertical
Power Spec LED