Introduction
Flat and inverted nipples can be the result of short
lactiferous (milk-bearing) ducts. The Niplette is designed to
lengthen these ducts by the application of gentle suction.
The Niplette can correct flat and inverted nipples and it has
proven to be a long-lasting solution for both cosmetic
purposes and to allow for breastfeeding.
The Niplette set includes:
-
Syringe (Fig. 1A) – 1 or 2 pcs*
-
Tube (Fig. 1C) with a thimble cup (Fig. 1B) – 1 or 2 pcs*
-
Disposable breast pads – 2 pcs
* See on the packaging for your specific set.
Intended use
The Philips Avent Niplette is intended to correct flat and
inverted nipples. The Niplette is intended for a single user.
Indications for use
The Philips Avent Niplette is indicated for use to correct flat
and inverted nipples which have developed as a result of
hereditary factors or during puberty. It is also indicated for
users having had unsuccessful surgery to obtain a cosmetic
correction.
Important safety information
Read this important information carefully before you use the
product and save it for future reference.
Contraindications
-
Do not use the Niplette during the last trimester of
pregnancy.
-
The Niplette is not suitable for lactating women.
-
Do not use the Niplette on flat and inverted nipples
developing later in life without medical advice. If in doubt,
consult your healthcare professional.
Undesirable side effects
When using the product, undesirable side effects that may
occur are pain, blisters, swelling, bleeding or discharge of
fluid. If you experience any of these symptoms, first decrease
the amount of suction. If the symptoms persist, contact a
healthcare professional.
Warnings to avoid swallowing of small parts and choking:
-
Always keep this product under adult supervision.
-
Keep all parts not in use out of the reach of children.
-
Do not allow children to play with small parts or packaging
materials.
Other warnings:
-
Inspect carefully before each use. If the Niplette appears
to be damaged or becomes damaged, stop using it and
throw it away.
-
Only use accessories or parts specifically recommended
by Philips to avoid unsafe situations.
-
Do not modify the product to avoid unsafe situations.
-
Do not use the on damaged skin.
-
Any serious incident that has occurred in relation
to this product should be reported to Philips via
www.philips.com/support
and to the competent authority
of the Member State in which the user is established.
Cleaning
Warning: Clean the Niplette before first use and
after each use.
Note: The Niplette is not suitable for any disinfection
method, for example boiling in water, sterilization in
microwave or in electric steam sterilizer, using alcohol-based
wipes. Do not clean in the dishwasher.
1
Detach the tube from the syringe. Do not remove the
thimble cup from the tube.
2
Clean the two parts in warm, soapy water and rinse under
the tap.
Warning: Do not use aggressive cleaning agents
when you clean the Niplette.
3
Assemble the parts.
4
Remove residual water from the tube by pushing the
syringe down.
5
Disassemble the parts and let them dry on a clean
surface.
Using the Niplette
1
Push the syringe firmly into the open end of the valve
(Fig. 2).
2
Hold the thimble cup over the nipple with one hand and
apply suction by pulling the syringe with the other hand
(Fig. 3). Pull as firmly as is comfortable. Do not pull too
hard. A small smear of lotion or cream at the base of the
Niplette will improve the seal and suction.
Warning: Start with minimal suction and gradually
increase the suction over time. Reduce the vacuum level
if you experience pain. Excessive suction force applied
to the nipple could cause pain, blisters, swelling,
bleeding or discharge of fluid.
3
When the nipple has been pulled out, let go of the
Niplette by holding the valve and by carefully separating
the syringe from the valve (Fig. 4).
4
You are now free to continue your daily activities wearing
the thimble cup and tube. It is easily concealed under
loose clothing. You can also wear the Niplette overnight.
Warning: Start wearing the product for a few hours
and gradually increase the time you are wearing it.
Depending on the duration of use, results can be
expected within 3–12 weeks.
5
To remove the Niplette, push the syringe into the valve to
release the vacuum.
Warning: Release the vacuum on the nipple before
re-applying the vacuum.
Storage
- Store in a cool, dry place.
Disposal
- According to local regulations.
Support
Visit
www.philips.com/support
for a list of frequently asked
questions or contact the Philips Consumer Care Center in
your country.
SCF152
SCF152
SCF152
Niplette
Philips Consumer Lifestyle BV
Tussendiepen 4, 9206 AD Drachten, The Netherlands
www.philips.com/avent
Trademarks are the property of Koninklijke Philips N.V.
© 2020 Koninklijke Philips N.V.
All rights reserved.
3000.052.3001.1 (2020-05-20 )
FSC
2
1
3
4
7
6
5
13
12
11
10
8
9
14
15