background image

UK

UK

12. Choosing the right teat for your baby

AVENT clear silicone anti-colic teats can be used on both the AVENT
VIA Feeding System and AVENT Feeding Bottles. AVENT teats are
clearly numbered on the side to indicate flow rate. 

9

8

2

1

3

4

Medium Flow – three holes 

Recommended for babies
3 months and older.

Fast Flow – four holes 

Recommended for babies
6 months and older.

Variable – one slot

With a slot instead of holes. 
Recommended for babies
3 months and older. 

Newborn – one hole 

Recommended for newborn 
and breastfed babies.

Slow Flow – two holes 

For a slightly faster flow. 
Recommended for 1 month+ 
and breastfed babies.

The teat is marked with three flow 
settings – I being the slowest and III 
being the fastest. To adjust the flow 
rate, turn the AVENT VIA Feeding 
System or Feeding Bottle while in 
baby's mouth and line up appropriate 
marker(s) to baby’s nose. Start with 
slow flow (I) and regulate the flow 
according to baby's feeding needs.

Teats comply to BS 7368: 1990

If you experience problems, please contact AVENT Customer Services on:
0800 289064 (UK); 1800 509 021 (IRL); 1300 364 474 (Australia National);
(02) 9457 0127 (Australia NSW only). You can also email us at:
[email protected] (UK/IRL); [email protected] (AUS). 
Alternatively, contact your health professional/breastfeeding adviser.

13. Troubleshooting Guide

Lack of suction

No milk being expressed

Pain when expressing

Milk is drawn up the 
petal massage cushion

Cracking/discolouration 
of pump parts

Lost or broken parts

Check that all the pump components have been assembled
correctly and that the white star valve is facing up with the
flatside into the bottle. Ensure that the diaphragm and let-
down massage cushion are fitted securely to the pump body 
and a perfect seal is created. 

Ensure suction is created and the pump is correctly assembled.
Relax and try again, expression may improve after practice.
Please refer to the ‘Hints to help you succeed’ section.

You may be pumping too hard. You do not need to use all 
the suction the pump can generate. Try depressing the handle
halfway and remember the 2-3 second pumping rhythm. 
Consult your health professional/ breastfeeding adviser.

Try removing and refitting the let-down massage cushion 
to ensure it is firmly attached and pushed far enough down 
the funnel. Try leaning slightly forward. Try releasing the handle
more frequently to empty the breast milk into the VIA Cup or
bottle. Refer to “How to use your AVENT ISIS Breast Pump”.

Avoid contact with antibacterial detergents/cleaners as these
can damage the plastic. Combinations of detergents, cleaning
products, sterilising solution, softened water and temperature
fluctuations may, under certain circumstances, cause the plastic
to crack. If this occurs, do not use. Contact AVENT Customer
Services for spare parts. The pump is dishwasher safe but food
colourings may discolour components. 

Spare parts are available through AVENT Customer Services, see
contact details below or visit our web-site at www.avent.com

7170-VIA+ISIS-UKEPIL#1-pgs.qxd  25/11/04  9:38  Page 8

All manuals and user guides at all-guides.com

Содержание AVENT ISIS

Страница 1: ... 97 44 35 Se quiser receber o nosso catálogo grátis se tiver dificuldades em comprar os nossos produtos por favor telefone nos 800 20 47 23 H P E UK 83 0081 0413 1 AVENT Suffolk CO10 7QS England Tel 44 1787 267 000 Fax 44 1787 267 001 www avent com Breast Pump with Storage System Extractor de Leche Con Sistema de Almacenamiento Bomba Tira Leite Com Sistema de Armazenamento 7170 VIA ISIS UKEPIL 1 c...

Страница 2: ...your baby your expressed breast milk 12 Choosing the right teat for your baby 13 Troubleshooting Guide 14 Other breastfeeding products from AVENT Instructions for use Please take five minutes to read through this leaflet BEFORE you use your AVENT ISIS Breast Pump for the first time Should you ever lose these instructions they are available on our website www avent com 6 1 7 IMPORTANT DO NOT LOSE T...

Страница 3: ...All manuals and user guides at all guides com ...

Страница 4: ... DO NOT OVERTIGHTEN 3 Place the assembled pump body and VIA Adaptor onto the VIA Cup i Twist gently clockwise until it catches DO NOT OVERTIGHTEN 4 Place the silicone diaphragm with stem d into the pump body f Make sure it fits securely around the rim by pressing down with your fingers to ensure a perfect seal This is easier if assembled while wet 5 Place the forked end of the handle e under the d...

Страница 5: ...slightly forward use cushions to support your back Make sure you have a glass of water nearby 5 Press the funnel and let down massage cushion of the pump firmly against your breast making sure that no air can escape otherwise there will be no suction 6 As you gently push down on the pump handle you will feel the suction on your breast You don t need to depress the handle fully to create a vacuum o...

Страница 6: ...ilk To feed your baby replace the VIA Lid with a sterilised VIA Adaptor locking ring dome cap and AVENT teat Frozen breast milk should be defrosted overnight in the refrigerator However in an emergency it can be defrosted in a jug of hot water Once thawed use within 24 hours Breast milk can be heated in the same way as any other bottle feed Stand the VIA Feeding System or Feeding Bottle in a bowl ...

Страница 7: ...to help you succeed section You may be pumping too hard You do not need to use all the suction the pump can generate Try depressing the handle halfway and remember the 2 3 second pumping rhythm Consult your health professional breastfeeding adviser Try removing and refitting the let down massage cushion to ensure it is firmly attached and pushed far enough down the funnel Try leaning slightly forw...

Страница 8: ...All manuals and user guides at all guides com ...

Отзывы: