philippi VSR 200 Скачать руководство пользователя страница 2

k

    V S R   2 0 0

Seite 2

  

       V2.2 - APR 2014

WARRANTY 

 

philippi elektrische systeme gmbh grants a two year limited and non-transferable warranty for the first 
buyer of this equipment, commencing on the date of purchase and covers defects in manufacturing, 
parts and materials. 
Production or material defects will be corrected without costs if:   
• the equipment is sent to us at the expense of the sender   
• an Invoice or proof of purchase (copy) is included  
• the equipment was used for its intended purpose   
• no unauthorized parts were added, and the equipment was not exposed to extreme conditions     
Not included in the warranty are damages from:    
• overvoltage on the inputs or reverse polarity 
• ingress of liquids, vapors, condensation, etc.  
• lightning 
Follow-up costs and normal wear and tear are not covered under warranty.  
In case of warranty the defect must be clearly specified. A detailed description of the 
defect will help to speed up the repair. 
Please note that we cannot accept carriage forward deliveries. 
 

EXCLUSION OF LIABILITY 

 

Both adherence to the operating instructions, and the conditions and methods used during installation, 
use and maintenance of the VSR, cannot be supervised by philippi electrical systems gmbh.  
Therefore we do not take any responsibility for loss, damage or costs, which develop due to incorrect 
installation and/or inappropriate use..

 

 

SAFETY REFERENCES 

 

x

 unauthorized changes to the equipment will invalidate the CE sign  

x

 the installation of the VSR may be made only by electrical specialists.  

x

 Important! Pay attention to the correct polarity of the batteries!  

 

 The assembly and operating instruction is a component of the VSR package. It must be kept  
(for reference). Importantly: - for later maintenance work - and for the use of subsequent owners of the 
equipment. 

 

DISPOSAL NOTE

 

 

Please take care of your local directives on waste electrical and electronic equipment. Please 
use collection points for waste electrical and  
electronic equipment. 

 

 

SCOPE OF DELIVERY 

 

x

 VSR200

Best.-Nr.: 7 0001 0120 

x

 Cover for bolts BA 2 RT(2 pcs.)

Best.-Nr.: 7 0010 4012 

 

ACCESSORIES (NOT INCLUDED IN DELIVERY) 

 

x

 Button 0-1 for Emergency ON  z.B. 21 x 14 mm

Best.-Nr.: 5 1801 1202 

    (or any other push button from our assortment)   
x LED without series resistor 5 mm green

Best.-Nr.: 6 0005 0621

Содержание VSR 200

Страница 1: ...y groups as soon as the voltage falls below the switch off threshold In addition the battery banks can be disconnected during the starting process The VSR 200 can be activated in an emergency by manual operation at the relay or by an optional control button to establish a connection between the battery groups in order to select the motor from both batteries emergency start function The VSR 200 is ...

Страница 2: ... to the operating instructions and the conditions and methods used during installation use and maintenance of the VSR cannot be supervised by philippi electrical systems gmbh Therefore we do not take any responsibility for loss damage or costs which develop due to incorrect installation and or inappropriate use SAFETY REFERENCES x unauthorized changes to the equipment will invalidate the CE sign x...

Страница 3: ...us must be connected to the minus of the on board power supply Terminal C Connection for an optional button for Battery parallel connection against minus Terminal L Connection for an optional external control LED against minus Terminal S Connection for Battery disconnection optional to disconnect the batteries during the start process or during charging with a charger with several outputs or to di...

Страница 4: ...t be switched off TECHNICAL DATA Rated voltage 12 V 24 V Operation voltage 9 32 V Rated current continous 200 A Cross section 95 mm Overload 5s 400 A Peak current 0 2 s 1500 A Switch ON Voltage thresholds 120 Sec 13 4 V 26 8 V 30 Sec 13 8 V 27 6 V Switch OFF Voltage thresholds 30 Sec 13 0 V 26 0 V 10 Sec 12 5 V 25 0 V 16 0 V 32 0 V at Over Volatge when C not set Power consumption Relais OFF 1 5 mA...

Отзывы: