Operation Mode (Parameter Number 5, Parameter Size 1) parameter to set the Operation Mode

Value

Description

0 — 

127

Bit 0: 1 means security mode; 0 means home automation mode. Bit 1: 1 means enable test 

mode; 0 means disable test mode. Notice: Bit0 and Bit1 will effect when the DIP Switch setting 

to program mode. If Bit1 is enabled, the Bit0 is useless. Bit 2: Disable the door/window function. 

Bit 3: Setting the temperature scale. 0: Fahrenheit, 1:Celsius Bit 4: Disable illumination report 

after event triggered. Bit 5: Disable temperature report after event triggered (Default 0)

Multi-Sensor Function Switch (Parameter Number 6, Parameter Size 1) parameter to set the sensor 

functions

Value

Description

0 — 

127

Bit 0: Disable magnetic integrate illumination. Bit 1: Disable PIR integrate Illumination. Bit 2: 

Disable magnetic integrate PIR (Default is Disable) Bit 3: When Bit2 is 0 (Enable), the device is 

install in the same room with the light? 0: In the same room(Default), 1: In the different room. Bit 

4: Disable delay 5 seconds to turn off the light, when door/window closed. Bit 5: Disable auto turn 

off the light, after door/window opened to turn on the light. Notice: If bit2 is zero, this setting is 

useless. Bit 6:Enable temperature monitoring. When this bit enable, the temperature changed 3 

degree Fahrenheit, it will report. And also the temperature over 140 degree Fahrenheit, it will 

report every 64 seconds. (Default 4)

PIR Re-Detect Interval Time (Parameter Number 8, Parameter Size 1) In the security mode, after the PIR 

motion detected, setting the re-detect time

Value

Description

3 — 127 8 seconds per tick, and minimum time is 24 seconds, default tick is 3 (24 seconds). (Default 3)

Turn Off Light Time (Parameter Number 9, Parameter Size 1) After turn on the light, setting the delay time to 

turn off the light when the PIR motion is not detected

Value

Description

4 — 127 8 seconds per tick, and minimum time is 32 seconds, default tick is 4 (32 seconds) (Default 4)

Auto Report Battery Time (Parameter Number 10, Parameter Size 1) interval time for auto report the battery 

level

Value

Description

1 — 127 30 minutes per tick and minimum time is 30 minutes, default tick is 12 (6 hours) (Default 12)

(c) 2012 Z-Wave Europe GmbH, Goldbachstr. 13, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwaveeurope.com - pp 6 

Содержание Z-Wave PHI PSM02

Страница 1: ...able and secure communication Each message is reconfirmed two way communication and every mains powered node can act as a repeater for other nodes meshed network in case the receiver is not in direct wireless range of the transmitter Z Wave differentiates between Controllers and Slaves Slaves are either sensors S transmitting metered or measured data or actuators A capable to execute an action Con...

Страница 2: ... controllers Product description The Z Wave 4 in 1 Sensor is designed with three detection sensors Door Window PIR Motion Temperature Illumination The Philio Multi Sensor is a Z Wave door window sensor motion sensor lighting sensor and temperature sensor in one package Thanks to this the PSM02 can be uses as a security device or home automation device e g to send an alarm when a motion is detected...

Страница 3: ...work This process is called Inclusion Devices can also leave a network This process is called Exclusion Both processes are initiated by the primary controller of the Z Wave network This controller will be turned into exclusion respective inclusion mode Please refer to your primary controllers manual on how to turn your controller into inclusion or exclusion mode Only if the primary controller is i...

Страница 4: ...sensor to send the warning message After powering up the divice needs several minutes to setup and work properly The device has a tamper switch which starts alarm when the device is forcibly removed Node Information Frame NI The Node Information Frame is the business card of a Z Wave device It contains information about the device type and the technical capabilities The inclusion and exclusion of ...

Страница 5: ... Set Level Parameter Number 2 Parameter Size 1 Setting the BASIC command value to turn on the light Value Description 255 0xFF 1 turns on the light Default 1 100 For dimmers 1 to 100 means the light strength PIR Sensitivity Parameter Number 3 Parameter Size 1 parameter to set the Sensitivity for the PIR Passiv Infrared Sensor Value Description 0 0 means disable the PIR motion 1 99 1 means the lowe...

Страница 6: ...window closed Bit 5 Disable auto turn off the light after door window opened to turn on the light Notice If bit2 is zero this setting is useless Bit 6 Enable temperature monitoring When this bit enable the temperature changed 3 degree Fahrenheit it will report And also the temperature over 140 degree Fahrenheit it will report every 64 seconds Default 4 PIR Re Detect Interval Time Parameter Number ...

Страница 7: ... tick is 12 6 hours Default 12 Auto Report Temperature Time Parameter Number 13 Parameter Size 1 interval time for auto report the temperature Value Description 1 127 30 minutes per tick and minimum time is 30 minutes default tick is 12 6 hours Default 12 Command Classes Supported Command Classes Battery version 1 Association version 2 Configuration version 1 Manufacturer Specific version 2 Versio...

Страница 8: ...s of removing Z Wave devices from the network Association is a control relationship between a controlling device and a controlled device Wakeup Notification is a special wireless message issued by a Z Wave device to annonces that is is able to communicate Node Information Frame is a special wireless message issued by a Z_Wave device to announce its capabilities and functions Disposal Guidelines Th...

Отзывы: