Philio PSP01 Скачать руководство пользователя страница 10

FCC Interference Statement 

This equipment has been tested and found to comply with the limits for

a Class B digital device, pursuant to Part 15 of the FCC Rules. These

limits are designed to provide reasonable protection against harmful

interference in a residential installation. This equipment generates, uses

and can radiate radio frequency energy and, if not installed and  used

in accordance with the instructions,  may cause  harmful interference to

radio   communications.         However,     there   is   no   guarantee   that

interference will not occur in a particular installation.  If this equipment

does cause harmful  interference to radio or television reception,  which

can be  determined by turning the equipment off and on,  the user  is

encouraged to try to correct the interference by one of the following

measures:

Reorient or relocate the receiving antenna.

Increase the separation between the equipment and receiver.

Connect the equipment into an outlet on a circuit different from

that to which the receiver is connected.

Consult   the   dealer   or   an   experienced   radio/TV   technician   for

help.

This device complies with Part 15 of the FCC Rules. Operation is subject

to the following two conditions: 

(1) This device may not cause harmful interference, and

(2)   This   device   must   accept   any   interference   received,   including

interference that may cause undesired operation. 

 

FCC Caution: Any changes or modifications not expressly approved by

the party responsible for compliance could void the user's authority to

operate this equipment. 

 

This transmitter must not be  co-located or  operating in  conjunction

with any other antenna or transmitter.

Warning

Do not dispose of electrical appliances as unsorted municipal waste,

use   separate   collection   facilities.   Contact   your   local   government   for

information   regarding   the   collection   systems   available.   If   electrical

appliances are disposed of in landfills or dumps, hazardous substances

can leak into the groundwater and get into the food chain, damaging

your health and well-being.

When replacing old appliances with new once, the retailer is legally

obligated to take back your old appliance for disposal at least for free

of charge.

10

Содержание PSP01

Страница 1: ...he front side They have the same function Both of them can inclusion exclusion reset or association from Z WaveTM network In the first time add the device into the Z WaveTM network First make sure the primary controller is in the inclusion mode And then power on the device just take out the insulation Mylar in the back side of the device The device will auto start the NWI Network Wide Inclusion mo...

Страница 2: ...ely please remove the front cover and press the tamper key once The device will wake up 10 seconds Z WaveTM Message Report Motion Report When the PIR motion detected the device will unsolicited to send the Sensor Binary Report to the nodes in the group 1 Sensor Type Motion 0x0C Sensor Value 0xFF Tamper Report When the 2 tamper keys in the device are pressed over 5 seconds The device will into the ...

Страница 3: ...imes NWI When the power on the device will check is it already adding to the network If doesn t it will auto start the NWI mode The LED will flash in every second and continue 30 seconds Until timeout or the device successful to inclusion by controller Wake When the power on the device will wake about 20 seconds In this duration the controller can communicate with the device Normally the device is...

Страница 4: ...etting of the configuration setting NO 4 the device will emit the signal to turn ON the lighting equipment those nodes in the group 2 And delay a while to turn OFF the lighting equipment The delay time is setting by the configuration setting NO 9 The PIR motion re detected interval in the Test Mode fixed to 6 seconds In the Home Automation Mode will start detect before turn OFF the lighting equipm...

Страница 5: ...5 ...

Страница 6: ...ar a click sound 2 Hold the front cover and pull back 3 Hold the front cover and pull up Replace the new battery and install the cover back 1 Put the front cover bottom to 1 1 and press down 2 Push the front cover top to 2 1 Choosing a Suitable Location 1 The recommended mounting height is 160cm 2 Don t let the device facing the window or the sunlight 3 Don t let the device facing the source of he...

Страница 7: ... hereinafter referred to as A tape and another is thinner hereinafter referred to as B tape you can use A tape for the test at the beginning The right way for A tape installation is stick it to the position below tamper key The thicker tape won t let the tamper key close so the sensor will enter the test mode You may test if installed position is good or not by this way After finish the test and d...

Страница 8: ... mode 0 means disable test mode Notice Bit0 and bit1 will effect when the DIP Switch setting to program mode If bit1 is enabled the bit0 is useless Bit2 Reserved always 1 Bit3 Setting the temperature scale 0 Fahrenheit 1 Celsius Bit4 Disable illumination report after event triggered Bit5 Disable temperature report after event triggered 6 Multi Sensor Function Switch 4 0 127 Multi Sensor function s...

Страница 9: ...rs 13 Auto Report Temperature Time 12 1 127 The interval time for auto report the temperature 30 minutes per tick and minimum time is 30 minutes default tick is 12 6 hours Z Wave Supported Command Class COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_VERSION COMMAND_CLASS_SENSOR_BINARY_V2 COMMAND_CLASS_ASSOCIATION_V2 COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 COMMAND_CLASS_WAKE_UP_V2 COMMAND_CLASS_SENSOR_MU...

Страница 10: ...to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation FCC Caution Any changes or modif...