PSM09-A/B

Recessed Door  Door lock Sensor

      

The PSM09 can detect the the door is open or not, and lock or unlock.

      The Recessed door sensor PSM09 is Base on  Z-Wave

TM

 technology.

      It is the Z-Wave

TM

 plus product, it support the security, OTA... Those newest 

features of the Z-Wave

TM

 technology. Z-Wave

TM

 is a wireless communication 

protocol designed for home automation, specifically to remotely control 
applications in residential and light commercial environments. The technology 
uses a low-power RF radio embedded or retrofitted into home electronics 
devices and systems, such as lighting, home access control, entertainment 
systems and household appliances.

      Notice: if user use some command,it have to check device is security bootstrap

otherwise some command can not increment.

Function Compare A/B

Door Sensor

Door lock Sensor

PSM09-A

V

V

PSM09-B

V

CAUTION

– 

replacement of a battery with an incorrect type that can defeat 

a safeguard (for example, in the case of some lithium battery 
types);

– 

disposal of a battery into fire or a hot oven, or mechanically 

crushing or cutting of a battery, that can result in an explosion;

– 

leaving a battery in an extremely high temperature surrounding 

environment that can result in an explosion or the leakage of 
flammable liquid or gas;

– 

a battery subjected to extremely low air pressure that may re-

sult in an explosion or the leakage of flammable liquid or gas

The marking information is located at the bottom of the apparatus.

Specification

Operating Voltage

DC3.6V 1000mAh

 (ER14250 Li-B

attery)

Range

Minimum 40M in door and 100M in outdoor, 

line of sight

Operating Temperature

-10°C ~ 40°C (85% humidity)

Storage Temperature

-20 C ~ 60°C

Location 

Indoor use only

Frequency Range

868.40 MHz, 869.85 MHz (EU)
908.40 MHz, 916.00 MHz (US)
920.9MHz, 921.7MHz, 923.1MHz (TW/KR/Thai/SG)

RF Maximum Power (peak)

+5dBm (peak)

RF Maximum Power (Average) -10dBm (Average)
FCC ID

RHHPSM09

Patent number

US 10,287,801 B1/ 3215012 (JP)
202017107537.0 (DE)

** Specifications are subject to change and improvement without notice.  

1

Содержание PSM09-A

Страница 1: ...that can defeat a safeguard for example in the case of some lithium battery types disposal of a battery into fire or a hot oven or mechanically crushing or cutting of a battery that can result in an explosion leaving a battery in an extremely high temperature surrounding environment that can result in an explosion or the leakage of flammable liquid or gas a battery subjected to extremely low air p...

Страница 2: ... ID allocated by Z WaveTM Controller means Remove or Exclusion Function Description Add 1 Have Z WaveTM Controller entered inclusion mode Pressing tamper key three times within 3 seconds to enter the inclusion mode If the learning code is successful the LED will flash slowly Remove 1 Have Z WaveTM Controller entered exclusion mode Pressing tamper key three times within 3 seconds to enter the exclu...

Страница 3: ... for receive the setting commands The wake up interval minimum setting is 30 minutes and maximum setting is 120 hours And the interval step is 30 minutes If the user want to wake up the device immediately please press the tamper key once The device will wake up 10 seconds Z WaveTM Auto Report After the device adding to the network it will auto report every 6 hours in default When it auto report it...

Страница 4: ... is allowed any value but no effect Security Network The device supports the security function When the device included with a security controller the device will auto switch to the security mode In the security mode the follow commands need using Security CC wrapped to communicate otherwise it will not response COMMAND_CLASS_ZWAVEPLUS_INFO COMMAND_CLASS_SUPERVISION COMMAND_CLASS_WAKE_UP COMMAND_C...

Страница 5: ...uitable Location 1 1 The recommended mounting position is above the bolt and the distance from the lock tongue is less than 4 cm 1 2 Infrared detection hole must be aligned downward with the lock tongue 1 3 As close as possible to the lock tongue the better 5 ...

Страница 6: ...ompany Philio Technology Corporation Address 8F No 653 2 Zhongzheng Rd Xinzhuang Dist New Taipei City 24257 Taiwan R O C www philio tech com FCC Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful in terference in a resid...

Страница 7: ...r transmitter Warning Do not dispose of electrical appliances as unsorted municipal waste use separate collection facilities Contact your local government for information regarding the collection systems available If electrical appliances are disposed of in landfills or dumps hazardous substances can leak into the groundwater and get into the food chain damaging your health and well being When rep...

Отзывы: