1.  In the first time, add the device into the Z-Wave

TM

 network.  First,

make sure the primary controller is in the inclusion mode. And then

power on the device, just take out the insulation Mylar in the back side

of   the   device.   The   device   will   auto   start   the   NWI   (Network   Wide

Inclusion) mode. And it should be included in 5 seconds. You will see

the LED light ON one second.

2. Let Controller associate with Group 1 of the device, any light switch

that intend to be turned on when  the device  trig please associate to

Group 2 of  the device.

3.  In the accessory pack. There are two type of double coated tape,

one is thicker (hereinafter referred to as A tape)  and another is thinner

(hereinafter referred to as B tape), you can use A tape for the test at

the beginning. The right way for A tape installation is stick it to the

position below tamper key. The thicker tape won't let the tamper key

close, so the sensor will enter the test mode, You may test if installed

position is good or not by this way.

After finish the test and decide to fix, then you can remove tape A, and

mounting the sensor by using tape B.  This will close the tamper key

and let the sensor enter normal mode.

Z-Wave Configuration Settings

NO.

Name

Default

Valid

Values

Description

2 Basic Set Level 255

1~100,

0xFF

Setting the BASIC command value to 
turn on the light. The 0xFF(-1) means 
turn on the light. For dimmer equipment 
1 to 100 means the light strength.

3 PIR Sensitivity

70

0~99 PIR sensitivity settings.

7

Содержание PSM02

Страница 1: ...s in the front side They have the same function Both of them can inclusion exclusion reset or association from Z WaveTM network In the first time add the device into the Z WaveTM network First make sure the primary controller is in the inclusion mode And then power on the device just take out the insulation Mylar in the back side of the device The device will auto start the NWI Network Wide Inclus...

Страница 2: ...he device immediately please remove the front cover and press the tamper key once The device will wake up 10 seconds Z WaveTM Message Report Motion Report When the PIR motion detected the device will unsolicited to send the Sensor Binary Report to the nodes in the group 1 Sensor Type Motion 0x0C Sensor Value 0xFF Door Window Report When the Door Window state changed the device will unsolicited to ...

Страница 3: ...setting NO 13 Power Up Procedure Battery Power Check When the power up the device will detect the power level of the battery immediately If the power level is too low the LED will continue flash about 5 seconds Please change another new battery PIR Warm Up When the power on the PIR need to warm up before operation The warm up time about 1 minute the LED will flash in every 2 seconds After finish t...

Страница 4: ...by configuration setting NO 5 Caution In the Home Automation Mode if the environment luminance higher than the setting the device won t report the message When the event triggered if the environment luminance is less than the setting of the configuration setting NO 4 the device will emit the signal to turn ON the lighting equipment those nodes in the group 2 And delay a while to turn OFF the light...

Страница 5: ...5 ...

Страница 6: ...ar a click sound 2 Hold the front cover and pull back 3 Hold the front cover and pull up Replace the new battery and install the cover back 1 Put the front cover bottom to 1 1 and press down 2 Push the front cover top to 2 1 Choosing a Suitable Location 1 The recommended mounting height is 160cm 2 Don t let the device facing the window or the sunlight 3 Don t let the device facing the source of he...

Страница 7: ...eferred to as A tape and another is thinner hereinafter referred to as B tape you can use A tape for the test at the beginning The right way for A tape installation is stick it to the position below tamper key The thicker tape won t let the tamper key close so the sensor will enter the test mode You may test if installed position is good or not by this way After finish the test and decide to fix t...

Страница 8: ...en the DIP Switch setting to program mode If bit1 is enabled the bit0 is useless Bit2 Disable the door window function Bit3 Setting the temperature scale 0 Fahrenheit 1 Celsius Bit4 Disable illumination report after event triggered Bit5 Disable temperature report after event triggered 6 Multi Sensor Function Switch 4 0 127 Multi Sensor function switch Using bit to control Bit0 Disable magnetic int...

Страница 9: ...e 30 minutes per tick and minimum time is 30 minutes default tick is 12 6 hours 12 Auto Report Illumination Time 12 1 127 The interval time for auto report the illumination 30 minutes per tick and minimum time is 30 minutes default tick is 12 6 hours 13 Auto Report Temperature Time 12 1 127 The interval time for auto report the temperature 30 minutes per tick and minimum time is 30 minutes default...

Страница 10: ...is equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that...

Отзывы: