Philio PSE04 Скачать руководство пользователя страница 6

*Play Sound:

Using   the   BASIC_SET   or   Sound_Switch_Tone_Play_Set   to   play   the

siren, BASIC_SET

 or 

Sound_Switch_Tone_Play_Set

 with Value 0xFF, the

Sound ID will be the same as the value which was set in Configuration
No.7

, 0x00 will stop to play.

Basic Set (V2) or Sound Switch Tone Pley Set (V1)

Value

Sound

0x00

Stop Play

0x01

Fire

0x02

Ambulance

0x03

Police

0x04

Alarm

0x05

Ding Dong

0x06

Beep

0xFF

Same as configuration NO.7 setting,

or sound switch configuration setting.

* Timing Report:

Beside   the   event   triggered   could   report   message,   the   device   also

support the timing unsolicited report of the status.

Battery level report: Every 6 hours report once in default.

It could be changed by setting the configuration NO. 6.

Low battery report: When the battery level is too low, every 30

minutes will report once.

Temperature report: Every 6 hours report once in default.

It could be changed by setting the configuration NO. 4. 

Notice:

  The configuration NO. 4 and 6 could be setting to

zero to disable the auto report. And the configuration NO. 1 could

change the tick interval, the default value is 30, if setting to 1, that

means the minimum auto report interval will be one minute. And please

notice if setting this value to zero, that means disable all of the timing

report except the low battery detection.

Power Up Procedure

*Battery Power Check

When the device power up, the device will detect the power level of the

battery immediately. If the power level is too low, device will report low

battery even every 30 minutes. Please change another new battery.

*Wake up beam

If   a   Z-Wave   controller   or   other   node   in   the   network   needs   to

communicate with a battery-powered device such as a door lock, the

controller sends a special beam signal. The purpose of this beam is to

wake up the FLiRS device.

When the FLiRS device receives this beam, it immediately fully wakes

up and then communicates with the controller or other Z-Wave device

utilizing standard Z-Wave protocol commands. If the device does not

hear   a   Beam   it   goes   back   to   full   sleep   for   another   period   until   it

partially awakes again and listens for a Beam.

Over The Air (OTA) Firmware Update

The device is supported with Z-Wave™ firmware update via OTA. 

1.

Set the Z-Wave

TM

 Controller into the firmware update mode.

2.

Choose the hex file to update the firmware. 

3.

Wait 10~15 minutes for completing the OTA process.

4.

Result of OTA will show in Z-Wave™ Controller log.

During   the   OTA   process,   please   DO   NOT   remove   the   power,

6

Содержание PSE04

Страница 1: ...ns All non battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network The device adopt the Z WaveTM 700 series chip when your Z WaveTM network system is all made by Z WaveTM 700 series devices The network system will have the advantages as below Concurrent multi channel support reduces external interference Better RF range improve ab...

Страница 2: ...ect to change and improvement without notice Troubleshooting Symptom Cause of Failure Recommendation The device can not join to Z Wave network The device may in a Z Wave network Exclude the device then include again Overview 2 ...

Страница 3: ...y Installation When the device report the low battery message The user should replace the battery to new one The battery type is AA 1 5V Please loosen the screw on the back cover to release the front cover 3 ...

Страница 4: ...ey in the 4th pressed and the LED will light ON 2 After 3 seconds the LED will turn OFF after that within 2 seconds release the tamper key If successful the LED will light ON one second Otherwise the LED will flash once 3 IDs are excluded and all settings will reset to factory default SmartStart 1 Product has a DSK string you can key in first five digit to increment SmartStart process or you can s...

Страница 5: ...des in the group 1 Notification Report V8 Notification Type Siren 0x0E Event Siren active 0x01 Siren idle 0x00 Temperature Report When the temperature differential over the device will unsolicited to send the Sensor Multilevel Report to the nodes in the lifeline group Sensor Type Temperature 0x01 Temperature differential report This function default is disable to enable this function by setting th...

Страница 6: ... report interval will be one minute And please notice if setting this value to zero that means disable all of the timing report except the low battery detection Power Up Procedure Battery Power Check When the device power up the device will detect the power level of the battery immediately If the power level is too low device will report low battery even every 30 minutes Please change another new ...

Страница 7: ...ch using bit control 0 Bit0 Disable Trigger Alarm 0 Enable 1 Disable 0 Bit1 Disable Sound Only using optical alarm 0 Enable 1 Disable 0 Bit2 Temperature Unit 0 Fahrenheit 1 Celsius 0 Bit3 Reserve 0 Bit4 Reserve 0 Bit5 Reserve 0 Bit6 Reserve 0 Bit7 Reserve 4 Auto Report Temperature Time 0x0C 0 255 The interval time for auto report the temperature 5 Temperature Differential Report 0x00 0 255 The tem...

Страница 8: ...battery according to the instructions Choosing a Suitable Location 1 The suitable ambient temperature for the module device is 0 C 40 C 2 Do NOT place the module device direct under sunlight in a humid place or in any location where they may contact moisture dirt dust 3 Do NOT place the module device where exists combustible substances or any source of heat fires radiators boiler etc Disposal This...

Страница 9: ...ing measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is sub ject to the following two conditions 1 This de...