Philio PHI PAN06 Скачать руководство пользователя страница 3

6-7-2020

manual.zwave.eu/backend/make.php?lang=en&sku=PHI_PAN06

manual.zwave.eu/backend/make.php?lang=en&sku=PHI_PAN06

3/5

1. Make sure a device is in factory reset state before including. In doubt exclude before include.

2. If inclusion still fails, check if both devices use the same frequency.

3. Remove all dead devices from associations. Otherwise you will see severe delays.

4. Never use sleeping battery devices without a central controller.

5. Dont poll FLIRS devices.

6. Make sure to have enough mains powered device to benefit from the meshing

Association - one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different

device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are

always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will

receive the same wireless command wireless command, typically a 'Basic Set' Command.

Association Groups:

Group Number

Maximum Nodes

Description

1

1

The Switch will report ON/OFF status of Relay1 and Relay2

2

1

The Switch will report ON/OFF status of Relay1

3

1

The Switch will report ON/OFF status of Relay2

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further

enhanced features.

IMPORTANT:

 Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the

desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the

same logic applies: Values greater than 32768 may needed to be given as negative values too.

Parameter 1: Slected Relay

If Controller not using Multi_Channel command class to access the relay of PAN06, you may configure the select value to react the Basic Command Class

or Binary Switch Command Class. 

Size: 1 Byte, Default Value: 3

Setting

Description

1

Relay 1

2

Relay 2

3

Relay 1 und Relay 2

Parameter 2: Edge or Pulse mode or Edge-Toggle mode

Manual switch S1 and S2 can set to Edge mode or Pulse mode or Edge-Toggle mode. 

Size: 1 Byte, Default Value: 1

Setting

Description

1

Edge Mode

2

Pulse Mode

3

Edge/Toggle Mode

Parameter 3: Restore switch state mode

Whenever the AC power return from lost, PAN06 will restore the switch state which could be SWITCH OFF

LAST SWITCH STATE

SWITCH ON. 

Size: 1 Byte, Default Value: 1

Setting

Description

0

Switch off

1

Last switch state

2

Switch on

Parameter 4: Auto off timer

Whenever PAN06 switches to on, the auto off timer begin to count down. After the timer decrease to zero, it will switch to off automatically. However if Auto off

timer is set as 0, the auto off function will be disabled. 

Size: 2 Byte, Default Value: 0

Setting

Description

0

Disable

1 - 32767

Seconds

Parameter 5: RF off command mode

Whenever a switch off command, BASIC_SET, BINARY_SWITCH_SET, SWITCH_ALL_OFF, is received, it could be interpreted as 4 variety of commands. 

Size: 1 Byte, Default Value: 0

Содержание PHI PAN06

Страница 1: ...security Otherwise it will automatically turn into a lower level of security to maintain backward compatibility For more information about Z Wave technology devices white papers etc please refer to www z wave info Product Description This Insert Switch allows controlling two independent loads both wirelessly via Z Wave and locally utilizing a traditional wall switch Thanks to its calibration techn...

Страница 2: ...xternally connected switch Three different modes are supported Edge Mode Die Position of the external switch determines the switching state of the relay After a wireless switching command it may be needed to operate the switch twice to return to the direct relation of switch position and relay state This mode is the factory default mode Toogle Mode Each ON Position of the external switch will togg...

Страница 3: ... needs or unlock further enhanced features IMPORTANT Controllers may only allow configuring signed values In order to set values in the range 128 255 the value sent in the application shall be the desired value minus 256 For example To set a parameter to 200 it may be needed to set a value of 200 minus 256 minus 56 In case of a two byte value the same logic applies Values greater than 32768 may nee...

Страница 4: ...are Platform SD3502 EAN 4713698571160 IP Class IP 20 Voltage 230 Der Endpunkt3 der Mehrkanal Befehlsklasse bezieht sich auf Relais1 und Relais2 Es kann überflüssig sein die Notwendigkeit Relais1 oder Relais2 einzeln zu steuern Wenn die Existenz von Endpunkt3 als 0 gesetzt ist wird der Endpunkt3 der Mehrkanal Befehlsklasse deaktiviert Load 2x 1500W Device Type On Off Power Switch Generic Device Clas...

Страница 5: ... primary controller in a Z Wave network Inclusion is the process of adding new Z Wave devices into a network Exclusion is the process of removing Z Wave devices from the network Association is a control relationship between a controlling device and a controlled device Wakeup Notification is a special wireless message issued by a Z Wave device to announces that is able to communicate Node Informatio...

Отзывы: