background image

The Sensor supports Command Classes including…

  COMMAND_CLASS_ZWAVEPLUS_INFO,
  COMMAND_CLASS_ASSOCIATION,
  COMMAND_CLASS_ASSOCIATION_GRP_INFO,
  COMMAND_CLASS_TRANSPORT_SERVICE_V2,
  COMMAND_CLASS_VERSION,
  COMMAND_CLASS_MANUFACTURER_SPECIFIC,
  COMMAND_CLASS_DEVICE_RESET_LOCALLY,
  COMMAND_CLASS_POWERLEVEL,
  COMMAND_CLASS_SECURITY_2,
  COMMAND_CLASS_CONFIGURATION,
  COMMAND_CLASS_NOTIFICATION_V3,
  COMMAND_CLASS_SECURITY,
  COMMAND_CLASS_SENSOR_MULTILEVEL_V11,
  COMMAND_CLASS_SUPERVISION
  COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2

Over The Air (OTA) Firmware Update

The device supports Z-Wave firmware update via OTA.
Before starting the update, please remove the front case of the device otherwise the
hardware check will fail.
Let the controller into firmware update mode, and press the front tamper key once to
start the update.
After firmware download is completed, the LED light will flash intermittently.

Overview

                                                                

Specification

Rated Voltage

DC5V from USB

Range

Minimum 40M in door and 100M in outdoor line of 

sight

Operating Temperature

-10°C 

~ 40°C (85% humidity)

Storage Temperature

-20 C ~ 60°C

Location

Indoor use only

Dimension

65(L) x 44.1 (W) x 56.3 (H) mm

CO2

0-5000ppm

Frequency Range

868.40MHz; 869.85MHz (EU)

908.40MHz; 916.00MHz (USA/Canada)
916MHz (Israel)

922.5MHz, 923.9MHz, 926.3MHz (JP)

RF Maximum Power (peak) +5dBm (peak)
RF Maximum Power 

(Average)

-10dBm (Average)

RF Modulation Type

FSK (Frequency-Shift Keying)

FCC ID

RHHPAT12

3

Содержание PAT12

Страница 1: ...d in any Z Wave network with other Z Wave certified devices from other manufacturers All non battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network The table below lists an operation summary of basic Z Wave functions Please refer to the instructions for your Z WaveTM Certificated Primary Controller to access the Setup function an...

Страница 2: ... mode the switch is in view from the LED for identification State Type LED Indication No node ID Under normal operation when the Switch has not been allocated a node ID the LED flashes on and off alternately at 30 second intervals By pressing On Off button it will stop flashing temporarily Learning When PAT12 is in learning mode If the learning code is successful the LED will flash slowly Programm...

Страница 3: ...tarting the update please remove the front case of the device otherwise the hardware check will fail Let the controller into firmware update mode and press the front tamper key once to start the update After firmware download is completed the LED light will flash intermittently Overview Specification Rated Voltage DC5V from USB Range Minimum 40M in door and 100M in outdoor line of sight Operating ...

Страница 4: ... by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help...