background image

Z-Wave 

CO2 Sensor 

PAT12-

A/B

The PAT12 CO2 sensor uses advanced NDIR (Non Dispersive Infra-Red) detect 
technology. The major advantages of NDIR sensors are low life cycle cost and  
precise and stable long-term operation.

The PAT12 CO2 sensor is a device that allows you to check the air quality in your 
home by detecting and measuring CO2 concentrations.

The PAT12 sensor is easy to use and very convenient for your home. Just set the 
sensor on the wall in the rooms you would like to control, and you are ready to go. 
Moreover, the PAT12 can be integrated to other Z-Wave certified devices, and 
controlled with Philio app “Home Mate 2.” You can now protect your family and your 
business and make sure that air you are breathing is safe. Set up your PAT12 to send 

regular notifications and take control even when not at home.

This device is a security enabled Z-Wave Plus product that is able to use encrypted Z-
Wave Plus messages to communicate to other security enabled Z-Wave Plus 
products.

This device must be used in conjunction with a Security Enable Z-Wave Controller in 
order to fully utilize all implemented functions.

The device adopts the Z-WaveTM 500 series chip when your Z-WaveTM network 
system is made by Z-WaveTM 500 series devices. This network system has the 
following advantages:

The product supports the Over The Air (OTA) feature for the products firmware 
upgrade.

Notice:

The PAT12 may exhibit a tolerance addition of 90ppm when first installed. This will get
corrected by the Self Calibration Feature within the first weeks of operation.
Please   continue   to   operate   the   PAT12   at   a   condition   that   was   exposed,   ambient
reference levels of air at 400 ppm CO2, for at least 7-Days.
Opening external windows can drop the CO2 levels down to 400ppm.

Function Compare A/B

CO2 Accuracy

PAT12-A

+/- 75 ppm or 10% of reading, whichever is greater

PAT12-B

+/- 30 ppm or 3% of reading, whichever is greater

1

Содержание PAT12-A

Страница 1: ...nabled Z Wave Plus product that is able to use encrypted Z Wave Plus messages to communicate to other security enabled Z Wave Plus products This device must be used in conjunction with a Security Enable Z Wave Controller in order to fully utilize all implemented functions The device adopts the Z WaveTM 500 series chip when your Z WaveTM network system is made by Z WaveTM 500 series devices This ne...

Страница 2: ...provided by the controller manufacturer 2 Press the include button of the PAT12 three times within 3 seconds to enter exclusion mode 3 Node ID has been excluded If the remove successful the LED light will flash for 120 seconds Reset 1 Press the include button of Use this procedure only the PAT12 three times within 3 seconds to enter inclusion mode 2 Within 1 second again press the include button o...

Страница 3: ...ess ful the LED light will flash slowly Z Wave Message Report CO2 Report When the CO2 Concentration differential over 1 percent in default or across the baseline level the device will unsolicited to send the Sensor Multilevel Report to the nodes in the group 1 Multilevel Sensor Report Sensor Type CO2 0x11 Note 1 This function default is enabled to disable this function by setting the configuration...

Страница 4: ... Specific 2 Highest granted Security Class Device Reset Locally 1 Highest granted Security Class Powerlevel 1 Highest granted Security Class Security 2 1 None Configuration 1 Highest granted Security Class Notification 8 Highest granted Security Class Security 0 1 None Sensor Multilevel 11 Highest granted Security Class Supervision 1 None Firmware Update Meta Data 4 Highest granted Security Class ...

Страница 5: ...his product should not be disposed with other household wastes throughout the EU To prevent possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use the return and collection systems or contact the retailer where the product was purchased They can take this p...

Страница 6: ...r help This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation FCC Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user s ...

Отзывы: