Philio PAT05 Скачать руководство пользователя страница 2

Remove
(Exclusion)

1.

Have Z-Wave

TM

 Controller entered exclusion mode.

2. Pressing tamper key three times within 2 seconds to enter the

exclusion mode.

3. Node ID has been excluded.

Reset

1. Pressing Include button of PAT05 three times within 2 

seconds will enter inclusion mode.

2.

 

Within 1 second, press Include button of PAT05 again for 5 

seconds.

3. Node ID has been reset excluded.

*notice:Please use this procedure only when the network 
primary controller is missing or otherwise inoperable.

SmartStart

1.  Product has a DSK string, you can key in first five digit to 

increment smart start process, or you can scan QR code.

2.  SmartStart enabled products can be added into a Z-Wave 

network by scanning the Z-Wave QR Code present on the 
product with a controller providing SmartStart inclusion. No 
further action is required and the SmartStart product will be 
added automatically within 10 minutes of being switched on in
the network vicinity.
*notice1:The QR code can be found on the device PAT05 or 
in the box.

Association

1. The PAT05 is an always listening Z-Wave device, so 

associations may be added or removed by a controller at any 
time. Or If your controller requires to have the PAT05 send a 
'node information frame' or NIF for associations, then 
pressing the On/Off button three times within 2 seconds will 
cause the PAT05 to send its NIF.

Note: The device support 1 groups. The group 1 is for 
receiving the report message.  A group one support 1 node 
maximum.

Adding a node ID allocated by Z-Wave Controller means inclusion. Removing a 

node ID allocated by Z-Wave Controller means exclusion.

Failed or success in including/excluding the node ID can be viewed from the Z-

Wave Controller.

Z-Wave

TM

 Message Report

eCO2

 Report:

When   the   eCO2   detected   state   changed,   the   device   will   unsolicited   to   send   the
“Sensor Multilevel Report” to the nodes in the group 1.
Sensor Type: eCO2 (0x11)
*** eCO2 Differential percent Report***
This function default is enabled, to disable this function by setting the configuration
NO.17 to 0.
In the default, when the eCO2 is changed to percentage, the device will report eCO2
information to the nodes in the group 1.

TVOC

 Report:

When   the   TVOC   detected   state   changed,   the   device   will   unsolicited   to   send   the
“Sensor Multilevel Report” to the nodes in the group 1.
Sensor Type: TVOC (0x27)
*** TVOC Differential percent Report ***
This function default is enabled, to disable this function by setting the configuration
NO.18 to 0.
In the default, when the TVOC is changed to percentage, the device will report TVOC
information to the nodes in the group 1.

Tamper Report:

The tamper keys are pressed over 8 seconds. The device will into the

alarm state. In that state, if any one of the tamper keys be released,

the device will unsolicited to send the report to the nodes in the group

1.

Notification Report (V8)
Notification Type: Home Security (0x07)

2

Содержание PAT05

Страница 1: ...eTM certified devices from other manufacturers and or other applications All non battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network The device adopt the Z WaveTM 500 series chip when your Z WaveTM network system is all made by Z WaveTM 500 series devices The network system will have the advantages as below Notice Once you hav...

Страница 2: ...05 to send its NIF Note The device support 1 groups The group 1 is for receiving the report message A group one support 1 node maximum Adding a node ID allocated by Z Wave Controller means inclusion Removing a node ID allocated by Z Wave Controller means exclusion Failed or success in including excluding the node ID can be viewed from the Z Wave Controller Z WaveTM Message Report eCO2 Report When ...

Страница 3: ...port the security function When the device included with a security controller the device will auto switch to the security mode In the security mode the follow commands need using Security CC wrapped to communicate otherwise it will not response COMMAND_CLASS_VERSION_V3 COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_ASSOCIATION_V2 COMMAND_CLASS_ASSOCIATION_...

Страница 4: ...difference return The Unit is 100ppb 0 means turn off TVOC detected function When there is a set value it means that it will exceed or fall below the report 9 TVOC Threshold line 2 0 1 100 TVOC difference return The Unit is 100ppb 0 means turn off TVOC detected function NO Name Def Valid Description When there is a set value it means that it will exceed or fall below the report 10 TVOC Threshold l...

Страница 5: ...his function the device will detect every percentage And when the lightSensor is over 10 percentage it will continue report Z Wave Supported Command Class Command Class Version Required Security Class Z Wave Plus Info 2 None Version 3 Highest granted Security Class Manufacturer Specific 2 Highest granted Security Class Security 2 1 None Device Reset Locally 1 Highest granted Security Class Associa...

Страница 6: ...ronment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use the return and collection systems or contact the retailer where the product was purchased They can take this product for environmental safe recycling Philio Technology Corporation 8F No 653 2 Zhongzheng Rd Xinzhuang Dist New Ta...

Страница 7: ...ice may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation FCC Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment This transmitter must not be co located or operating in conjunction with any other an...