Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can 

adapt the function better to user needs or unlock further enhanced features.

IMPORTANT: Controllers may only allow to configure signed values. In order to set values in the range 128 

… 255 the value sent in the application shall be the desired value minus 256. For example: to set a 

parameter to 200? it may be needed to set a value of 200 minus 256 = minus 56. In case of two byte value 

the same logic applies: Values greater than 32768 may needed to be given as negative values too.

Basic Set Level (Parameter Number 2, Parameter Size 1) Setting the BASIC command value to turn on the 

light

Value

Description

255

0xFF(-1) turns on the light. (Default)

1 — 100 For dimmers 1 to 100 means the light strength

Light Threshold (Parameter Number 4, Parameter Size 1) Setting the illumination threshold to turn on the 

light. When the event triggered and the environment illumination lower then the threshold, the device will 

turn on the light

Value

Description

0

0 means turn off illumination detected function And never turn on the light.

1 — 100

1 means darkest. 99 means brightest. 100 means turn off illumination detected function. 

And always turn on the light (Default 99)

Operation Mode (Parameter Number 5, Parameter Size 1) parameter to set the Operation Mode

Value

Description

0 — 127

Bit 0: Reversed. Bit 1: Reversed. Bit 2: Disable the door/window function. Bit 3: Setting the 

temperature scale. 0: Fahrenheit, 1:Celsius Bit 4: Disable illumination report after event 

triggered. Bit 5: Disable temperature report after event triggered. (Default 0)

(c) 2012 Z-Wave Europe GmbH, Goldbachstr. 13, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwaveeurope.com - pp 5 

Содержание PSM01

Страница 1: ...munication Each message is reconfirmed two way communication and every mains powered node can act as a repeater for other nodes meshed network in case the receiver is not in direct wireless range of the transmitter Z Wave differentiates between Controllers and Slaves Slaves are either sensors S transmitting metered or measured data or actuators A capable to execute an action Controllers are either...

Страница 2: ...rts a Detector and a Magnet They are designed to be fitted to doors or windows with the Magnet mounted on the opening part and the Detector mounted on the fixed frame Opening the protected door window will remove the magnetic field trigger the detector and generate an alarm condition if the system is armed The sensor can also applied to automatic light control one scenario is to get the illuminati...

Страница 3: ...is called Exclusion Both processes are initiated by the primary controller of the Z Wave network This controller will be turned into exclusion respective inclusion mode Please refer to your primary controllers manual on how to turn your controller into inclusion or exclusion mode Only if the primary controller is in inclusion or exclusion mode this device can join or leave the network Leaving the ...

Страница 4: ...n of the device is confirmed by sending out a Node Information Frame Beside this it may be needed for certain network operations to send out a Node Information Frame Tripple Click the Temper Switch on the backside sends out a Node Information Frame Associations A Z Wave devices control other Z Wave devices The relationship between one device controlling another device is called association In orde...

Страница 5: ...immers 1 to 100 means the light strength Light Threshold Parameter Number 4 Parameter Size 1 Setting the illumination threshold to turn on the light When the event triggered and the environment illumination lower then the threshold the device will turn on the light Value Description 0 0 means turn off illumination detected function And never turn on the light 1 100 1 means darkest 99 means brighte...

Страница 6: ...R motion is not detected Value Description 4 127 8 seconds per tick and minimum time is 32 seconds default tick is 4 32 seconds Default 4 Auto Report Battery Time Parameter Number 10 Parameter Size 1 interval time for auto report the battery level Value Description 1 127 30 minutes per tick and minimum time is 30 minutes default tick is 12 6 hours Default 12 Auto Report Door Window State Time Para...

Страница 7: ...ultilevel Sensor version 5 Manufacturer Specific version 2 Technical Data Battery Type 1 CR123A Explorer Frame Support Yes SDK 6 1 Device Type Slave with routing capabilities Generic Device Class Binary Sensor Specific Device Class Routing Binary Sensor Routing No FLiRS No Firmware Version 1 0 Explanation of Z Wave specific terms Controller is a Z Wave device with capabilities to manage the networ...

Страница 8: ... device to annonces that is is able to communicate Node Information Frame is a special wireless message issued by a Z_Wave device to announce its capabilities and functions Disposal Guidelines The product contains batteries Please remove the batteries when the device is not used Do not dispose of electrical appliances as unsorted municipal waste use separate collection facilities Contact your loca...

Отзывы: