22
9.2 Before installing the hob, make sure that
•
The work surface is square and level, and no structural members interfere
with space requirements.
• The work surface is made of a heat-resistant material.
• If the hob is installed above an oven, the oven should have an internal cooling
fan.
• The installation will comply with all clearance requirements and applicable
standards and regulations.
• A suitable independent switch providing full disconnection from the mains
power supply is incorporated in the permanent wiring, mounted and
positioned to comply with the local wiring rules and regulations.
The independent switch must be an approved type and provide a 3 mm air
gap contact separation in all poles (or in all active [phase] conductors if the
local wiring rules allow for this variation of the requirements).
• The independent switch will be easily accessible to the customer with the hob
installed.
• Please consult local building authorities and by-laws if in doubt regarding
installation.
• Please use heat-resistant and easy-to-clean finishes (such as ceramic tiles)
for the wall surfaces surrounding the hob.
9.3
After installing the hob, make sure that
• The power supply cable is not accessible through cupboard doors or drawers.
• There is adequate flow of fresh air from outside the cabinet to the base of the
hob.
• If the hob is installed above a drawer or cupboard space, a thermal protection
barrier is installed below the base of the hob.
• The independent switch is easily accessible by the customer.
9.4 Before locating the fixing brackets
The unit should be placed on a stable, smooth surface (use the packaging). Do
not apply force onto the controls protruding from the hob.
9.5 Adjusting the bracket position
Fix the hob on the work surface by screw 4 brackets on the bottom of hob (see
picture) after installation.
Adjust the bracket position to suit for different table top thickness.