Electrical connection
The mains power supply must correspond to the rating indicated on the plate situated inside the hood. If
provided with a plug connect the hood to a socket in compliance with current regulations and positioned in
an accessible area, after installation. If it not fitted with a plug (direct mains connection) or if the plug is not
located in an accessible area, after installation, apply a double pole switch in accordance with standards which
assures the complete disconnection of the mains under conditions relating to over-current category III, in
accordance with installation instructions.
Warning!
Before re-connecting the hood circuit to the mains supply and checking the efficient function,
always check that the mains cable is correctly assembled.
The hood is provided with a special power cable ; if the cable is damaged, request a new one from Technical
Service.
Mounting
Before beginning installation:
• Check that the product purchased is of a suitable size for the chosen installation area.
• Remove the charcoal filter/s if supplied. This/these is/are to be mounted only if you want to use the hood in
the filtering version.
• Check (for transport reasons) that there is no other supplied material inside the hood (e.g. packets with
screws, owner’s manual, etc.), eventually removing them and keeping them.
• Remove the tape on the vent.
• Turn the unit off and unplug it from the outlet.
In the case of the presence of panels and/or walls and/or lateral wall units check that there is sufficient space
to install the hood and that access to the command panel is easy.
Expansion wall plugs are provided to secure the hood to most types of walls/ceilings. However, a qualified
technician must verify suitability of the materials in accordance with the type of wall/ceiling. The wall/ceiling
must be strong enough to take the weight of the hood.
Do not tile, grout or silicone this appliance to the
wall. Surface mounting only.
The minimum distance between the supporting surface for the cooking equipment on the hob and the lowest
part of the range hood must be not less than 45cm from electric cookers and 55cm from gas or mixed cookers.
If the instructions for installation for the gas hob specify a greater distance, this must be adhered to.
Only for some models
An aesthetic flue can be purchased as an optional accessory. Check with the authorized dealer whether the
model in your possession envisages this possibility.
We advise installing the hood after having purchased the flue to check with certainty the most suitable