EN - 7
02/2015
Copyright © 2015, Fast ČR, a. s.
b) Insert dowels into the drilled holes A, B, C, D. Check that the dowels are properly inserted.
c) Use screws (5.5 x 45) to attach the hanging plate to the ceiling. Check that the hanging plate if fi rmly and
properly attached.
A
B
C
D
FRONT
Hanging hole
Hanging plate
2) Installation of the angle sections
The front angle sections must be installed in the left-right direction and the rear angle sections the other
way round.
Attach the angle section to the motor base according to the illustration. You can then set the height of
the range hood by setting various positions of the angle sections relative to the motor unit. Check that
all angle sections are installed at the same height and that the front part of the motor unit is facing in the
same direction as the front part of the hanging plate and control panel.
FRONT
Connection of the front angle
sections – left to right direction
Connection of the rear angle
sections – right to left direction
Place for connecting
the angle sections
Front part of
the motor unit
3) Installing the chimney to the motor unit
Insert the inner chimney into the outer chimney. To temporarily join the chimney use the screws from the
motor unit. The chimney will then not fall during the installation to the hanging plate. The screw holes of
the inner chimney should fi t with the motor unit.
Содержание PEI 904
Страница 1: ...RANGE HOOD USER S MANUAL PEI 904...
Страница 23: ...ODSAVA PAR N VOD K OBSLUZE PEI 904...
Страница 45: ...ODS VA P R N VOD NA OBSLUHU PEI 904...
Страница 48: ...SK 2 02 2015 Copyright 2015 Fast R a s...
Страница 67: ...SK 21 02 2015 Copyright 2015 Fast R a s POZN MKY...