Philco PEI 12715 Скачать руководство пользователя страница 16

EN - 14

 04/2012

Copyright © 2012, Fast ČR, a. s.

PART 5: OPERATION 

Remove the protective foil from the control panel. 

The range hood is controlled only by means of a remote control. 

 button

 – This button serves to turn the range hood on / off . When it is pressed the range hood motor starts 

running at 1 (lowest power). An LED indicator light (on the far left side) will light up on the range hood. If you 
increase the exhaust power level to 2 then two LED indicators will be lit, etc. 

– button 

- This button serves to reduce the exhaust power level. Each time it is pressed the exhaust power level 

will decrease by 1 level. The lowest level is 1.

+ button 

- This button serves to increase the exhaust power level. Each time it is pressed the exhaust power 

level will increase by 1 level. The highest level is 4.

Timer 

Press and hold the – button for at least 2 seconds and the timer function will be turned on for a period 
of 15 minutes. The LED indicator light on the far right will be lit. The motor will automatically turn off  after 
15 minutes or if you change the exhaust power level.

NOTE: 
Use the range hood together with the stove. This will ensure the correct air exhaust. We recommend to 
leave the range hood running a few minutes longer than the stove to ensure that all odours are extracted.

Lighting

The range hood is equipped with 3 groups lights. 
1.  

Group

: press the 

 button, while the lights are off  and the 2 middle lights will turn on. 

2.  

Group

: press the 

 button again, the 2 middle lights will turn off  and 4 lights on the sides will turn on. 

3.  

Group

: press the 

 button once more and all the lights will turn on. 

If you press the 

 button again the lights will turn off . 

NOTE: 
If you do not perform any operation within 4 hours, the range hood will turn off  automatically.

Operating tips

1.  Regularly clean the aluminium fi lters and regularly replace the carbon fi lters. 
2.  Use the medium exhaust power level. Only use the highest power level when necessary. 
3.  To ensure proper ventilation, leave windows closed while the appliance is turned on. 

Содержание PEI 12715

Страница 1: ...RANGE HOOD USER S MANUAL PEI 12715 PEM 14 PEM 8...

Страница 2: ...Dear customer Thank you for buying a PHILCO brand product So that your appliance serves you well please read all the instructions in this user s manual...

Страница 3: ...ppliance 5 Placement 5 Assembly and installation 6 Carbon filter 8 Ventilation 8 PART 4 INSTALLATION OF THE EXTERNAL MOTOR UNIT 9 PEM 14 External motor unit 9 PEM 8 External motor unit 11 PART 5 OPERA...

Страница 4: ...ce heavy objects on it it must not be tangled and it must not be stepped on Do not locate the power cord in or on heat sources such as stoves heating or other generators of heat Otherwise this may dam...

Страница 5: ...e for their safety Attention when transporting or carrying The packaging materials are from recyclable materials so dispose of them in an environmentally conscientious manner according to regulations...

Страница 6: ...ION OF THE APPLIANCE 1 Power cord 4 Function indicator lights 2 Lighting 5 Aluminium filter 3 Protective cover 1 2 3 4 5 Remote control a b d c a Turn the appliance on off b Increase the exhaust power...

Страница 7: ...ring transport contact authorised service centre Do not use a damaged appliance under any circumstances IMPORTANT Ensure that children do not play with the packaging material Dimensions of the applian...

Страница 8: ...onnect and move to the side freely standing or built in stoves so that you have easier access to the rear wall or ceiling If this is not possible place protective material on to the work area cooktop...

Страница 9: ...Cable leading from the external ventilation unit 3 Place the range hood against the ceiling and secure it in place using screws 4 Attach one end of the aluminium pipe to the range hood flange and the...

Страница 10: ...when the carbon filter is not installed Do not use the appliance without the aluminium filter installed Replacing the carbon filter 1 For the correct operation of the appliance it is necessary to inst...

Страница 11: ...together with the screws Screw M5x40 screws into the M5 thread on the motor unit base 2 Drilling mounting holes Drill 8mm holes A B in the installation location of the external motor unit and insert...

Страница 12: ...e air outlet in the top part of the range hood Insert the other end into the air inlet of the external motor unit 2 Connecting the external motor unit to a chimney Place one end of the aluminium tube...

Страница 13: ...l motor unit 1 Installation of hanging brackets To hang the external motor unit it is necessary to first install 2 L shaped hanging brackets which are supplied together with the screws Screw M5x40 scr...

Страница 14: ...lation of aluminium tubes 1 Connecting the range hood to the external motor unit Connect the flexible aluminium tube to the air outlet in the top part of the range hood Insert the other end into the a...

Страница 15: ...use supports to strengthen the tube structure Cable connection After completing the entire installation and connecting the tubes you can connect the cables of the external motor unit to the range hoo...

Страница 16: ...5 minutes The LED indicator light on the far right will be lit The motor will automatically turn off after 15 minutes or if you change the exhaust power level NOTE Use the range hood together with the...

Страница 17: ...ulb Install a light bulb with the same parameters in reverse sequence Cleaning Aluminium filters capture dust and fat from the extracted air It is necessary to regularly wash these filters ideally onc...

Страница 18: ...t use petrol benzene thinners or any other solvents coarse cleaning agents steel wool or any sponges with steel wool WARNING You may put the aluminium filters in a dishwasher The colour of the alumini...

Страница 19: ...ts are not working Check that the power plug is properly inserted in a properly grounded power socket with the parameters 220 240 V 50 Hz Check if you have pressed the button Check whether the light b...

Страница 20: ...EN 18 04 2012 Copyright 2012 Fast R a s PART 8 TECHNICAL SPECIFICATIONS Input voltage 220 V 50 Hz Air outlet diameter 120 mm NOTE All the here mentioned data is subject to change...

Страница 21: ...s and help in preventing the potential negative impact on the environment and human health which could be caused as a result of improper liquidation of waste Please ask your local authorities or the n...

Отзывы: