Installation

1. Remove the cartridge from the mounting plate to ease

installation. Thread two (2) male quick-connect fittings onto each

end of the cartridge. Find one fitting plugged into the black input

hose and the other packaged with the Purity-Light.

2. Attach the mounting plate vertically to the wall. Position the

mounting plate with the strap at eye level to ease cartridge

replacement. Re-attach the cartridge to the mounting plate with the

strap. NOTE: The water flows down through the cartridge for proper

results.

3. Loosen the 4 screws holding the case

lid slightly and remove the tape sticking

out of the case (this will activate the

batteries). Re-tighten all 4 screws.

Remove the backing tape from the Velcro

strips (both places) on the black case and

stick to the backboard above the hose

hanger (as shown right) and central to the

backboard with the wire sticking out to

your left. Press gently until both strips

have adhered properly.

4. Attach one end of the input hose to the water supply and the other

end to the top of the cartridge. Attach the Purity-Light to the

bottom of the cartridge, using the quick-connect coupling.

5. Connect the blue output hose to the threaded bottom of the

Purity-Light. Thread the yellow quick-connect from the Watering

Gun to the output hose. Attach the Watering Gun, or Flow

Restrictor, to the output hose. Turn on the water and ensure all con-

nections are water tight. Operate the Gun for a few seconds to flush

out any residue in the system. NOTE: When using the Deionizer

without a Gun, use the provided Flow Restrictor when activating the

cartridge.

Activate Cartridge

To activate a new deionizer cartridge after installation, allow between

5-10 gallons of water to flow through the cartridge, using either the

Flow Restrictor or a watering gun. This activates the resin that

deionizes the water. The Purity Light will begin to flash green when

enough water has passed through the cartridge.

Operation

1. Turn on the water and squeeze the Watering Gun trigger until all

the air is exhausted and a smooth, steady flow emerges. The sys-

tem is now operational. If the water pressure is above 75 psi

(6 bar), the user must order the optional pressure regulator, PS-PR.

2. When finished, turn off the water and operate the Gun to relieve

the pressure on the hoses. Coil the hose and store on the hanger

provided.

3. As the cartridge becomes exhausted, the Purity-Light will begin to

blink Red. This is the signal for cartridge replacement. The water is

still pure and usable for a very limited time after the light turns red.

NOTE: Do not discard the quick-connect fittings with the cartridge.

Replace Batteries when the purity light goes out.

Model PS-300 Deionizer

Installation & Operating Instructions

Flashing Green Light - Deionizer is ready to dispense battery water

Flashing Red Light - The cartridge needs to be replaced.

No Light-Power problem, replace batteries, or check A/C power.

PAK939:PAK939.qxd 3/12/2009 1:24 PM Page 2