background image

 

 
 

POE62U Characteristics 

WWW.PHIHONG.COM 

Input/Output Case Ports 

3 ¾ NPT holes compatible with standard ¾ 
NPT conduit piping or Phihong wire gland 
PGLAND750 with fully waterproof AC and 
RJ45 cables. 

Network Switch 

Network Switch must be Environment Rated 
B as per paragraph 33.4.1.1 of the 
IEEE802.3at standard. 

 

 

POE62U Dimension Diagram unit:mm 

 

 

 

Single Cable Gland - PGLAND750* Dimension Diagram unit:mm 

 

 

 

Double Cable Gland - PGLAND750-2* Dimension Diagram unit:mm 

 

 

 

Note *: Cable Glands are sold separately 

Содержание POE62U-560G

Страница 1: ...ccess Points Safety Approvals cUL UL CE Mechanical Characteristics without Mounting Bracket Length 252 1mm 9 93in Height 78mm 3 07in Width 176mm 6 93in Weight 1 7Kg 3 75lb Mechanical Characteristics with Mounting Bracket Length 300mm 11 81in Height 82mm 3 23 Width 184mm 7 24in Weight 2 83kg 6 24lb Output Specifications Notes 1 Consult factory for availability Phihong is not responsible for any err...

Страница 2: ... 5 to 90 EMI FCC Part 15 Class B EN55022 Class B Isolation Test Primary to Secondary 4242 VDC for 1 minute 10mA Primary to Field Ground 2121VDC for 1 minute 10mA Output to Field Ground 2121VDC for 1 minute 10mA Immunity ESD IEC61000 4 2 Level 3 RS IEC61000 4 3 Level 3 EFT IEC61000 4 4 Level 2 Surge IEC61000 4 5 Level 3 CS IEC61000 4 6 Level 3 Voltage Dips IEC61000 4 11 Harmonic EN61000 3 2 Class A...

Страница 3: ...GLAND750 with fully waterproof AC and RJ45 cables Network Switch Network Switch must be Environment Rated B as per paragraph 33 4 1 1 of the IEEE802 3at standard POE62U Dimension Diagram unit mm Single Cable Gland PGLAND750 Dimension Diagram unit mm Double Cable Gland PGLAND750 2 Dimension Diagram unit mm Note Cable Glands are sold separately ...

Страница 4: ...but not orientation limited The enclosure is provided with a steel 2mm thick zinc plated mounting bracket When mounting utilize the holes in the mounting bracket plate 10mm holes 8 places The preferred method of mounting is to a vertical 4 inch or 6 inch pole using 2 3 8 x 16 U bolts If mounting on a flat surface to sheetrock or wood and or others material use 4 M6 fasteners Other fasteners may be...

Страница 5: ...by all appropriate National laws and regulations Installation Instructions 1 The unit is packaged fully closed with the mounting bracket pre installed remove from packaging and loosen the four captive screws located at the top of the midspan so that the lid can be lifted easily 2 Using a Philips screwdriver remove the four screws holding the protective covering for the PC Board and the two screws ...

Страница 6: ... spade lugs Pair and secure ground line and neutral to the appropriate positions on the three pin terminal block and reattach the protective covering Note if using the cable gland PGLAND750 the outer seal nut needs to be fully tightened to close rubber seal to protect against ingress of water 6 Using waterproof outdoor rated Cat5e Ethernet cable thread through cable glands or conduit piping to the...

Отзывы: