background image

sequence of orange, orange and blue, blue.

: Press up or down button to the desired temperature. When desired ambient

temperature is reached, the heater will automatically stop heating. When the

ambient temperature drops below the desired temperature 2°C, the heater will

resume heating.

Remote Control Battery Replacement:

Replace with a CR2025 battery and follow the diagram at the back of remote handset

to install the new battery.

Maintenance:

WARNING:

Completely disconnect power before attempting any maintenance or

cleaning, to reduce the risk of fire or electric shock. Maintenance should only be

performed by a certified technician.

Cleaning:

Before cleaning any parts of the fireplace make sure to first turn off the controls and

then unplug the unit from power source.

CAUTION:

Wait until the unit has completely cooled before attempting any cleaning.

Cleaning Glass Panel

: Remove dust with clean dry cloth. Remove fingerprints

and other marks from glass door by using a clean damp cloth. Do not use abrasive

cleaners or spray liquids on glass door surfaces.

Metal and metal painted parts should be cleaned with clean damp cloth only. Do not

use abrasive cleaners or spray liquids on these surfaces.

Содержание AH-FP-30F

Страница 1: ...MANUAL AH FP 30F AH FP 36F AH FP 40F AH FP 48F ATTENTION 1 Find a location for the electric heater that is protected from direct sunlight 2 Do not plug the electric heater into the power outlet befor...

Страница 2: ...acility for examination electrical or mechanical adjustment or repair 6 Under no circumstance should this electric heater be modified Parts having to be removed for servicing must be replaced by a cer...

Страница 3: ...erforming any cleaning maintenance or relocation of the heater 19 For off season storage keep in a dry place NOTE Procedures and techniques that are considered important enough to emphasize CAUTION Pr...

Страница 4: ...This heater can be installed in two ways which can be selected according to your preference Type 1 Built in Wall Clearance Please allow a minimum of 0 5 spacing from the rear of the unit to a wall Wa...

Страница 5: ...36 75 x 6 313 x 17 125 AH FP 48F 48 x 6 2 x17 7 44 75 x 6 313 x 17 125 Step 1 1 Find the two mounting screws and remove them 2 Remove the front cover by pulling it upward See Fig A 1 and Fig A 2 Fig A...

Страница 6: ...ter can be mounted properly and leveled Step 2 Drill 4 holes 8 mm 5 16in in diameter and 43 mm 1 7in deep on the marked locations For holes that do not hit stud use the supplied wall anchor Install th...

Страница 7: ...ulling it upward See Fig D 1 and Fig D 2 Fig D 1 Fig D 2 Step 5 Mount the heater on wall using the keyhole slots of the metal bracket at the back of the heater See Fig E Make sure that the mounting br...

Страница 8: ...g screws See Fig F Fig F Step 7 Replace the front cover and secure it with two mounting screws See Fig G Fig G OPERATION After reading all the instructions make sure that all the fireplace controls ar...

Страница 9: ...e ambient temperature drops below the desired temperature 2 C the heater will resume heating Operation by The Remote Control Press this button to turn ON the fireplace The unit will beep Press again t...

Страница 10: ...maintenance or cleaning to reduce the risk of fire or electric shock Maintenance should only be performed by a certified technician Cleaning Before cleaning any parts of the fireplace make sure to fi...

Отзывы: