5-2 

PM15-2/PM15-4 PARTS LIST continued 
 

N.P.N. 

R36 KNOB 

Knob, Raise Voltage 

Phenix 
 

1860260 

SW1 

Switch, Main Power, Lighted, Latching 1 Pole EAO 31-261 

1860265 

SW5 

Switch, Guard, Lighted, Latching 2 Pole 

EAO 31-262 

1355310 

SW3,SW4 
KNOBS 

Knobs for Voltmeter, Currentmeter Range 
Switches 

 

1863040 

SW3,SW4 

Switch, Range, Voltmeter, Currentmeter, 2 
Pole, 2-6 Pos. 

PA2002 

3111696 

CKT. BOARD 
ASSY. 

PCB 1169 PM15 Control Board Assembly 

Phenix 

PARTS 

– PCB 1169 CIRCUIT BOARD 

1424015 

B1 

Buzzer, Intervox, 24V, 35mA, BS2316P-24C  Allied 623-1906 

1093175 

C1 

Capacitor, .27

f, 50 VDC 

Digikey P4530-ND 

1095800 

C2 

Capacitor, 10

f, 20V 

Newark 47F386 

1092050 

C3,C9 

Capacitor, .01

f, 1kV 

Newark 18F2727 

1098470 

C4,C5 

Capacitor, Electrolytic, 470uf, 35V 

Newark 95F2430 

1095825 

C8,10 

Capacitor, Electrolytic, 10uf, 25V 

Newark 18F154 

1094438 

C13 

Capacitor, 2.2

f, 50V 

Newark 29F027 

1152285 

CON1,4 

Connector, 8 Pin, Red 

Allied 512-3243 

1152286 

CON1,4 

Connector, Board, 8 Pin 

Allied 512-3306 

1152260 

CON2,3,6,7,9 

Connector, 4 Pin, Red 

Allied 512-3239 

1152261 

CON2,3,6,7,9 

Connector, Board, 4 Pin 

Allied 512-3302 

1152230 

CON8 

Connector, 12 Pin, Red 

AMP-1-640440-2 

1152231 

CON8 

Connector, Board, 12 Pin 

AMP-1-640454-2 

1780025 

DI-6 

Diodes  

Digi-Key 1N4007 

1701033 

K1 

Relay, 2 Pole, 120 VDC 

 

1701323 

K2 

Relay, 4 Pole, RY4S-UDC24V, IDEC 

Scott  

1157340 

K2 Socket 

Socket, 4 Pole, Printed Circuit 

Newark 23N3605 

1700920 

K3 

Relay, 2 Pole, 12VDC, Omron G5A-237P 

Digi-Key Z707-ND 

1111692 

PCB 

Printed Circuit Board, Control 

Phenix 

1794005 

Q1 

Voltage Regulator, +12V, MC78M12CT 

 

1794006 

Q2 

Voltage Regulator, -12V, LM320T-12 

 

1803100 

Q3 

C106D SCR 

Allied 858-2057 

1723300 

R1,R26 

Resistor, 68k

, .5W, 1% 

 

1761090 

R2,30 

Resistor, 10 k

, Type 43P Pot. 

Newark 12F4409 

1761502 

R3,20,27 

Resistor, 50 k

, Type 43P Pot. 

Newark 12F4411 

1722615 

R6 

Resistor, 20 k

, .25W, 1% 

 

1734050 

R7 

Resistor, 49.9 k

, .25W, 1% 

 

1722082 

R10,11,33,39 

Resistor, 1 k

, .25W, 1% 

 

1760050 

R14 

Resistor, 50 

, Type 43P Pot. 

Newark 12F4402 

1720201 

R15 

Resistor, 180 

, .5W, 1% 

 

1760900 

R16 

Resistor, 1 k

, Type 43P 

Newark 12F4406 

1722075 

R17 

Resistor, 1.5 k

, .5W, 1% 

 

1761052 

R18 

Resistor, 5 k

, Type 43P 

Newark 12F4408 

Содержание PM15-2

Страница 1: ...OPERATIONS AND APPLICATIONS MANUAL MODEL NUMBER PM15 2 PM15 4 15 kV DC HIGH POTENTIAL TESTER WITH MEGOHMMETER Version 1 0...

Страница 2: ......

Страница 3: ...TION NOTES DESCRIPTION SPECIFICATIONS CONTROLS AND CONNECTIONS 2 FRONT PANEL CONTROLS AND METERS INPUT OUTPUT CONNECTIONS SET UP AND OPERATION INSTRUCTIONS 3 INSTALLATION TEST LEAD CONNECTIONS OPERATI...

Страница 4: ...Equipment have been listed below for your reference Become familiar with your instrument before performing an actual test Know your work area check that all circuits are de energized and locked out N...

Страница 5: ...an assistant operator where appropriate to keep non essential personnel away from the test site 7 When testing cables the conductors at the distant end should be isolated from each other and taped 8 W...

Страница 6: ...ers Input 120 Volts AC 50 60 Hz single phase 1 Amp or 220 Volts AC 50 60 Hz single phase 5 Amps Output Regulated 0 15 kV DC continuously adjustable with manual control 0 2mA PM15 2 0 4mA PM15 4 Negati...

Страница 7: ......

Страница 8: ...will sound until voltage control is returned to zero Currentmeter Megohmmeter The currentmeter range is selected by the five position rotary switch The switch setting indicates the full scale current...

Страница 9: ...ltage Current Trip This control located below the currentmeter range select switch allows the operator to set the level of leakage current measured by the instrument before high voltage shutdown occur...

Страница 10: ...order to measure currents to return in guard mode Ground This terminal is to be connected to the facility ground black cable provided Leakage current or insulation resistance values associated with t...

Страница 11: ...connect the test leads 6 Connect the AC Line cord to the power module and to the appropriate AC Power Source see unit specification tag either 120V or 220V TEST LEAD CONNECTIONS An understanding of th...

Страница 12: ...ate and remain recessed NOTE If the Voltage Control has not been set to Zero the overcurrent alarm will sound To silence this alarm insure that the voltage control is in its full counter clockwise pos...

Страница 13: ...click into position 6 Observe that the Kilovolt meter indicates zero 0 output 7 Turn off the high voltage power supply by depressing the High Voltage power switch Observe that this switch is no longer...

Страница 14: ...to the Test Set depending on the design Nothing is connected to the Guard Both stray leakage to earth ground and leakage through the Test Specimen is indicated on the current meter This configuration...

Страница 15: ...on the current meter Any current associated with the Guard bypasses the current meter Leakage current through the test specimen is indicated on the current meter Stray leakage to earth ground is not i...

Страница 16: ...4 1 SCHEMATIC Drawing Number Description 9109080 PM15 2...

Страница 17: ...r Supply 15kV 2mA PM15 2 Ultravolt 15A24 N30 E T0B6 1 1590174 H V POWER SUPPLY Power Supply 15kV 4mA PM15 4 Ultravolt 15C24 N60 E T0B6 ELECTRICAL PARTS COMPONENTS 1 1152590 Module Power Entry Corcom 6...

Страница 18: ...2 3306 5 1152260 CON2 3 6 7 9 Connector 4 Pin Red Allied 512 3239 5 1152261 CON2 3 6 7 9 Connector Board 4 Pin Allied 512 3302 1 1152230 CON8 Connector 12 Pin Red AMP 1 640440 2 1 1152231 CON8 Connect...

Страница 19: ...istor 110 k 25W 1 1 1722080 R29 Resistor 2 2 k 5w 12 2 1722600 R31 38 Resistor 10 k 25W 1 1 1720180 R34 Resistor 100 25W 1 1 1894335 T1 Transformer ST4 24 Newark 01F027 5 1356300 TP1 5 Test Points Min...

Страница 20: ...g parts to include the serial number of the unit as well as the part number of the replacement part When your purchase order is received at our office a representative of Phenix Technologies will cont...

Страница 21: ...for Return Cause of Defect If Phenix Technologies Inc deems return of the part appropriate it will then issue an Authorization for Return If return is not deemed advisable other inspection arrangement...

Отзывы: