background image

VTC-1D user manual  

 

Phason 

4  

2009-06-19 

 

To extend probe cables 

1.

 

Slide three pieces of heat shrink tubing over the wires: one for the red wire, one for the black wire, and 
one for both. 

2.

 

Strip the ends of the wires and then twist them together. 

3.

 

Solder the wires together using rosin-core flux solder—DO NOT use acid core solder.  

4.

 

Slide the heat shrink tubing over the solder joints.  

5.

 

Shrink the tubing using a heat gun. 

 

 

Getting started 

When power is applied to the VTC-1D, the following displays: 

1.

 

88

 displays for approximately 0.25 seconds (start-up). 

2.

 

00

 displays for approximately 1 second (self-test). 

3.

 

60

 displays for approximately 1 second. The 

60

 indicates that the power system is 60Hz. 

4.

 

The display flashes between the temperature display and 

PF

. The 

pf

 indicates a power interruption has 

occurred. To clear the 

PF

, click the switch to the right.  

The control is now in ‘normal’ mode.  

 

Display alerts 

Alert  Description 

P S  

The temperature probe or sensor cable has short circuited. 

P D  

The temperature probe is damaged or the connecting wire is broken. 

t S  

‘

 

The Temperature knob has accidentally been turned. The display will alternately flash 

tS

 

and the ambient temperature. The control will not accept the new setting until the switch is 
clicked to the set position.  

    or 

‘

 

The voltage switch is set to 230 volts, but the incoming power is 115 volts. Check the 
voltage switch. 

P F  

The power has been interrupted. The display will flash between PF and the temperature. To 
clear the alarm, click the switch to the right. The control will function normally. 

Содержание VTC-1D

Страница 1: ...idle mode Adjustable temperature set point Adjustable temperature differential Three second full power turn on to minimize fan ice up Two digit LED display Fahrenheit and Celsius display Error code di...

Страница 2: ...the enclosure Use watertight strain reliefs or conduit connectors at all cable entry points Before removing electrical knockouts remove the cover to prevent damaging the control Do not make additiona...

Страница 3: ...idelines and the guidelines below when extending cables Use two wire 18 AWG jacketed cable Phason recommends Belden 9408 Alpha 5052 or an equivalent Extension cable is also available from Phason For m...

Страница 4: ...ower system is 60Hz 4 The display flashes between the temperature display and PF The pf indicates a power interruption has occurred To clear the PF click the switch to the right The control is now in...

Страница 5: ...99 N A External knob Temperature differential di 1 to 20 F 0 6 to 12 C 6 F Internal trimmer Off set back oS 0 to 16 F 0 to 9 C 5 F Internal trimmer F or C ambient temp F C 22 to 99 F 30 to 38 C F Int...

Страница 6: ...b to the desired setting while holding the switch to the right The temperature set point can be between 32 and 98 F 0 and 38 C 3 Release the switch You must hold the switch to the right while turning...

Страница 7: ...factor calculate the correction as follows 1 Set the idle speed properly For more information see Setting minimum ventilation in idle mode on page 8 2 Set the differential to 10 F with the internal tr...

Страница 8: ...g the voltage If you are unsure see your fan dealer for the minimum idle voltage for your fan motor 8 Press and hold the switch to the right 9 Turn the Temperature knob to the desired temperature set...

Страница 9: ...ture set point When the temperature is between 80 F and 86 F the differential temperature fan speed changes proportionally with the temperature If the temperature increases fan speed increases If the...

Страница 10: ...mperature fan speed changes proportionally with the temperature If the temperature increases fan speed increases If the temperature decreases fan speed decreases When the temperature is at or above 86...

Страница 11: ...t that is labelled as non corrosive electronics grade or neutral cure such as GE Silicone RTV6780B RTV 142 or RTV 162 Do not use a sealant that is labelled as acetic acid cure or acetoxy cure These se...

Страница 12: ...rovide proof of purchase upon request All transportation charges for products submitted for warranty must be paid by the purchaser Except to the extent prohibited by applicable law no other warranties...

Отзывы: