SSC-1D installation guide 

4  

2009-09-14 

 

Operation 

The SSC-1D controls the temperature in a room by switching fans, lamps, or heaters on or off as 
the temperature drops below or exceeds the temperature set point. The set point is the desired room 
temperature and can be set between 32 and 98°F (0 and 38°C).  

 

‹

 

When the SSC-1D is in cooling mode

, the control switches on the load when the temperature 

exceeds the set point. 

‹

 

When the SSC-1D is in heating mode

, the control switches on the load (lamps or heaters) when 

the temperature drops below the set point.  

 

Switch position 

Function 

 

‘

 

Displays the ambient temperature 

 

‘

 

Allows you to view and adjust the temperature set point 

‘

 

Clears alarms 

 

‘

 

Allows you to verify if the control is in heating or cooling mode 

‘

 

Allows you to verify if the control is in Fahrenheit or Celsius mode

 

 

 

Setting the temperature set point    

1.

 

Press and hold the switch to the right.  
The current TEMP SET displays. 

2.

 

Turn the knob to the desired setting while holding the switch to the right. The TEMP SET can 
be between 32 and 98°F (0 and 38°C). 

 

 

You must hold the switch to the right while turning the knob. If this is not done 
correctly, the display flashes between 

tS

 and the temperature display. This means 

the knob has been turned without holding the switch. The control will not accept the 

new setting until the switch is clicked to the right. 

 

Содержание SSC-1D

Страница 1: ...heaters when the temperature drops below the set point Features Single stage output Heating and cooling modes Adjustable temperature set point Two digit LED display Fahrenheit and Celsius display Err...

Страница 2: ...SSC 1D Refer to the wiring diagram 1 Set the voltage switch A to the correct position for the line voltage used 2 Set jumper C to the correct position for the temperature units Fahrenheit or Celsius...

Страница 3: ...obe cables You can extend temperature probe cables to lengths of up to 500 feet Follow the temperature probe guidelines and the guidelines below when extending cables Use two wire 18 AWG jacketed cabl...

Страница 4: ...Displays the ambient temperature Allows you to view and adjust the temperature set point Clears alarms Allows you to verify if the control is in heating or cooling mode Allows you to verify if the con...

Страница 5: ...ur SSC 1D last longer To prevent damage to the control perform the following steps after the first two weeks of operation and once a year after that 1 Switch off the power to the control 2 Remove the...

Страница 6: ...D wipe the surface with a damp cloth Be careful when washing the room using a high pressure washer DO NOT spray the control using a high pressure washer this can damage the control and will void the w...

Страница 7: ...Phason SSC 1D installation guide 10940304 7...

Страница 8: ...pair the unit effecting all necessary parts replacements without charge for either parts or labor Conditions Installation must be done according to Phason s enclosed installation instructions The prod...

Отзывы: