![Phason FHC-1D Скачать руководство пользователя страница 5](http://html1.mh-extra.com/html/phason/fhc-1d/fhc-1d_user-manual_1536695005.webp)
Phason
FHC-1D user manual
11140706
5
Connecting the temperature probe
Follow the guidelines below and connect the temperature probe as shown in the diagram on page 4.
Do not run the probe cable in the same conduit as AC power cables
Do not run the sensor cable beside AC power cables or near electrical equipment.
When crossing other cables or power lines, cross them at a 90 degree angle.
Using four-zone averaging
The FHC-1D can monitor the temperature in four
different zones. The control takes an average of the
four temperatures and operates according to the
average temperature.
To use four-zone averaging, you must connect four
temperature probes to the unit, as shown to the right.