Phantom PHDEOK12L Скачать руководство пользователя страница 6

HANGING YOUR FIXTURE, continued

IN A GROW ROOM SETTING

We recommend using the rachet/carabiner method of hanging.
1.  Install two eye screws or J-hook screws (not included) approximately 24" apart in a stable 

ceiling or structural surface. If available, ceiling joists are best. If you can’t use joists, insert 

expansion anchors into the ceiling. Be sure to use anchors and hooks rated to hold at least 

50 lbs each.

2.  Tie the ends of the hangers’ lines to your hooks in the ceiling, then hook the carabiners 

through the eye bolt in the ballast housing (

1

) and the hole in the armature nose (

2

).

3.  Adjust the hanging height of the fixture to your desired height using the rachet. We 

recommend our Hydrofarm heavy Duty Light Riser (item HLH1002).

•  The lamp may require 10–30 minutes cooling time before restarting.
•  After you plug the reflector in, the bulb may require several minutes to reach its full brightness. 

In the event of a momentary power interruption, the bulb will not restart immediately.

•  Some variation in the color of light emitted by the bulb is not unusual, especially in the first 

100 hours of operation.

•  Never pull the cord to unplug the reflector, pull the plug only.
•  Avoid scratching the bulb, subjecting it to undue pressure, or getting it wet when it is hot; 

these actions may cause the bulb to break.

•   In the event of bulb breakage, immediately unplug the reflector to prevent exposure to 

ultraviolet energy, which may be harmful to eyes and skin.

•  Keep room temperature below 95°F, with adequate air circulation by fan in the growing area.
•  The DE lamp produces very high-intensity light and was originally designed for commercial  

growing operations. Please take care to consider proximity to plants when installing your 
fixture. You may want to allow more vertical space between the plant canopy and the fixture 
to mitigate the high-intensity light and heat in the plant area.

•  Always use a heavy-duty 3-pronged grounded timer, rated for at least 15 amps. Many 7-day 

digital timers are not rated for 1000W lamps. Unplug ballast when changing or removing the 
lamp. Failure to do so can cause ballast failure or improper diagnosis.

TIPS

1

2

6

Содержание PHDEOK12L

Страница 1: ...UAL LOW PROFILE 1000W LIGHTING SYSTEMS ENCLOSED and OPEN PhantomDELowProfileEnclosedLightingSystemPHDESK12L PhantomDELowProfileOpenLightingSystemPHDEOK12L INSTRUCTIONS EN FRANÇAIS 12 INSTRUCCIONES EN ESPAÑOL 24 ...

Страница 2: ...nd lamp life For information on additional Phantom products please visit Hydrofarm com WARNING FAILURE TO FOLLOW OUR GUIDELINES COULD RESULT IN ELECTRICAL SHOCK Do not touch move spray or clean your light fixture when it is plugged in Allow it to cool down before handling Recommended mounting clearance for your fixture is 8 12 on all sides Do not mount directly to any surface Make sure to disconne...

Страница 3: ...hantom DE LP Lighting System enclosed or open B Phantom Pro 2100 µmol s DE Lamp excluding NL systems C 120V Power Cord 240V power cord BACD10 available separately D RJ14 Cables x2 E RJ Splitter F Wire Hanger x2 B C D E A F PHDESK12L PHDEOK12L 3 ...

Страница 4: ...up Cathode Arc Tube Quartz Outer Jacket DIAGRAM A 1 Before installing the lamp make sure it is oriented so that the burner filament the long wire that runs along the full length of the arc tube is positioned upward facing the top inside surface of the reflector as seen in DIAGRAM A 2 Ensure that the wire ends leads are not bent or frayed as this will prevent proper installation The wire ends shoul...

Страница 5: ...loves whenever possible when handling lamp to minimize fingerprints and oils left on the lamp If the lamp needs cleaning after installation use a soft dry cotton cloth to wipe off fingerprints skin oils HANGINGYOUR FIXTURE IMPORTANT Before you begin make sure your light system is unplugged IN A GREENHOUSE SETTING 1 Simply place the hook like curved end of the included wire hanger through the eye b...

Страница 6: ...art immediately Some variation in the color of light emitted by the bulb is not unusual especially in the first 100 hours of operation Never pull the cord to unplug the reflector pull the plug only Avoid scratching the bulb subjecting it to undue pressure or getting it wet when it is hot these actions may cause the bulb to break In the event of bulb breakage immediately unplug the reflector to pre...

Страница 7: ...able Always keep low voltage data cables and high voltage AC power harness as far as possible from each other for stable signal transmission Avoid coiling data cables as well as AC harnesses in tight coils Excess cable should be managed by creating long loops as opposed to tight coils PHANTOM with RJ PX Port HID Fixtures Note Zone A and Zone B can be set up in one room or in two separate rooms RJ ...

Страница 8: ... do represent individual flashes black dots represent time that the LED is unlit between flashes They also represent the relative time duration of signals each dot still represents one half second For example the Too high voltage signal is shown as two red dots followed by two black dots This indicates two red flashes of one half second each followed by one second of a dark unlit LED TROUBLESHOOTI...

Страница 9: ...yellow flashes with medium long off interval Too high voltage occurred in past Input voltage was too high in the past See above reset Three rapid red flashes with brief off interval Too high temperature Electronics temperature is too high max 115 C 239 F There is temperature sensor in the PCB of the ballast If it senses the internal ballast temperature reaches 1100C the LED will start to blink The...