.CALIBRATION
When to calibrate
Calibration may be required when it is initially installed, if the scale is moved
to a substantial distance.
This is necessary because the weight of a mass in one location is not
necessarily the same in another location. Also, with time and use, mechanical
deviations may occur.
Calibration :
linearity calibration:
1. turn on the scale and than turn it off.
2. press and hold [TARE] and than turn on the scale, LCD will show LINE
on first line,CAL-0 (flashed) on the second line and AD value on the third line.
3.When the AD value is stable, press [ZERO] to calibrate ZERO, after 2 or 3
seconds, the second line will show 1.0000.
4. Place 1kg weight on the platform , and press [ZERO] when the stable A/D
value is displayed, after 2 or 3 seconds, the display will show 2.0000.
5. Place 2kg weight on the platform , and press [ZERO] when the stable A/D
value is displayed, after 2 or 3 seconds, the display will show3.0000.
6. Place 3kg weight on the platform , and press [ZERO] when the stable A/D
value is displayed, after 2 or 3 seconds, the display will show0.0000 and now
calibration is finished.
7. Turn off the power, then turn on the power again, place some weight on the
platform to make sure whether weighing is correct, if not, repeat steps 1-6.
Single segment calibration:
1.
turn on the scale and than turn it off.
2.
press and hold
[ZERO
] and than turn on the scale, LCD will show
SCALE on first line, CAL-0 (flashed) on the second line and AD value on
the third line.
3.
Press
[SAMPLE/UNIT]
to select calibration unit kg or lb.
4.
After the stable A/D value is displayed, press
[ZERO]
to calibrate ZERO,
after 2 or 3 seconds, the second will show 0.
5.
Set calibration weight through input 0 to 9 and than place the calibration
weight you had set, Press
[ZERO]
to calibrate, after the stable indicator
light, press
[ZERO]
key, the second line of display will show 00000 and
now calibration is finished.
6.
Turn off the power, then turn on the power again, place some weight on
the platform to make sure whether weighing is correct, if not, repeat steps
1-6.
5
P.
MEMORY [M+]
KEY is used when accumulation the counts data, this data
are memorized by pressing this key and could be accumulated up to 99
counts.
Q.
MEMORY CANCEL [MC]
KEY is used for canceling the memorized
data.
R.
[TOTAL]
KEY is used for the alternation of changing normal counting
and memory data recalling.
S.[SAMPLE/UNIT](lb/Kg).
Press the key to selected weight unit;Once the
unit is selected ,the selected unit indicate the different calibration and
weighing unit.
Ⅲ
. OPERATION:
A.
TARE
a.
Reduce tare weight:
.Place the empty container on the platter.Press [TARE] key then the tare
indicator is turned on the WEIGHT display shows Zero.
. When remove the container from the platter after reduced the weight,
then the WEIGHT display shows with minus sign.
b.
Clearing the previous tare value:
.Remove weights from the platter then press [TARE] key so that the Tare
indicator turns off and WEIGHT display returns to Zero.
B. SAMPLE SETTING:
There are two sample setting method:
a.
Number setting:
(In case of counting the unknown unit weight)
. Place the certain numbers of sample on the platter, total weight is display
in WEIGHT display.Set the numbers of sample through numeric keys, set
numbers is showed in UNIT WEIGHT display with flickering.
. Press the
[SAMPLE/UNIT]
key, UNIT WEIGHT display shows the
averaged unit weight per piece and TOTAL display shows the numbers of
sample.
b.
Unit weight setting:
(In case of unit weight is already known)
. Set the unit weight data then numbers are display with flickering in
UNIT WEIGHT display.. Press
[UNIT WEIGHT]
key, then flickering of
UNIT WEIGHT display is stopped.
c. Press
[CE]
key for cancel the previous unit weight and sample setting.
C
.ALARMING FUNCTION: To avoid counting error. This scale has useful
alarming function to inform operator the counting error feasibility in case of
sample number shortage or weight shortage of sample unit weight.
2
WWW.PHANTOMSCALES.COM