● Symbols on the Type Label 
 

Symbol 

Explanation 

 

CE FCC CB ROHS mark

 

The device complies with the requirements of the applicable CE FCC CB ROHS 

guidelines.

 

 
●Important Safety Instructions 
When using the product, please do remember the below information to avoid the fire, 
lightning or other personal injury: 

 

Warning! 

Ensure  input  DC  voltage  no  more  than  Max.  DC  voltage  .Over  voltage  may 

cause  permanent  damage  to  solar  charge  controller  or  other  losses,  which  will 

not  be  included  in  warranty!  This  chapter  contains  important  safety  and 

operating instructions. Read and keep this operation guide for future reference.

 

 

Warning! 

Authorized service personnel  must  disconnect both DC and battery bank  power 

from the solar charge controller before attempting any  maintenance  or cleaning 

or working on any circuits connected to the solar charge controller.

 

 
● Before using the solar charge controller, please read all instructions and cautionary 

markings  on  the  solar  charge  controller,  and  all  corresponding  sections  of  this 
guide. 

●  Please  use  components  and  parts  recommended  or  sold  by  I-Panda  New  Energy. 

Otherwise may result in a risk of fire, electric shock, or injury to person. 

● To avoid a risk of fire and electric shock, make sure that existing wiring is in good 

condition and that wire is not undersized. Do not operate the solar charge controller 
with damaged or substandard wiring. 

● Do not disassemble the solar charge controller. It contains no user-serviceable parts. 

See  Warranty  for  instructions  on  obtaining  service.  Attempting  to repair  the  solar 
charge controller by yourself may result in a risk of electric shock or fire and will 
make your warranty invalid. 

●  To  reduce  the  risk  of  electric  shock,  authorized  service  personnel  must  use 

insulating tool to operate the device. 

● Keep away from flammable, explosive materials to avoid fire disaster. 
● The installation place should be away from humid or corrosive substance. 
●  To  reduce  the  chance  of  short-circuits,  authorized  service  personnel  must  use 

insulated tools when installing or working with this equipment. 

 
 
 

Содержание HT-MPPT-192V 50A

Страница 1: ...HT MPPT Solar Charge Controller 48V 40A 50A 60A Series User s Manual...

Страница 2: ...ety Instructions 4 3 Unpacking 6 4 Assembly 6 5 MPPT controller Connection 7 6 Commissioning 9 7 Meaning of LED and LCD function 10 8 Technical Parameter 13 9 Maintenance and Cleaning 14 10 Storage an...

Страница 3: ...components must be stored in the immediate vicinity of the charge controller and must be accessible at all times 1 4 Symbols Used The following types of safety messages and general information appear...

Страница 4: ...harge controller can become hot during operation Avoid contact during operation And never put any goods onto the equipment under load Warning Due to high input working voltage please be cautious other...

Страница 5: ...nd cautionary markings on the solar charge controller and all corresponding sections of this guide Please use components and parts recommended or sold by I Panda New Energy Otherwise may result in a r...

Страница 6: ...re 4 Assembly 4 1 Operator technical personnel 4 2 Selecting the Mounting Location 4 2 1 Dimensions L W H 280mm 180mm 90mm 4 2 2 Net Weight Weight 2 8kg 4 2 3 Ambient Conditions Danger Danger to life...

Страница 7: ...sipation Direction Safety clearance Sides 20cm Top 30cm Bottom 20cm 5 MPPT controller Connection 5 1 Safety 5 2 Connections of the PV power system Danger Danger to life due to high voltage in the sola...

Страница 8: ...bout 1 2 So we suggest the solar charge controller install near PV module in order to save wire and reduce DC loss DC Output Solar charge controller is designed for battery charging Table 4 Cable and...

Страница 9: ...Fasten the lid to the enclosure using eight screws 3 Connect the cables leading from the solar charge controller to the battery 4 Switch on the circuit breaker and the disconnection unit 5 Then turn o...

Страница 10: ...Power light green FUNCTION KEY function key LED information Condition Alarm Red Power Blue Standby Green Power on off off on Charge off on on Fault on off on Bat Chose Type off off off In voltage cons...

Страница 11: ...different mode MPPT Information of LCD in different mode Model 1 Display Boot Mode 1 mode website 2 BAT checking 3 PV volt checking 4 In volsen checking 5 Out volsen checking Remarks Shown above autom...

Страница 12: ...ow solar irradiation In Relay Fault Input relay interrupted Out Volt Low battery voltage is lower than 9 V Out Volt High short circuit overload or over current at battery or PV array also before first...

Страница 13: ...ess the key to choose the type of the battery which you need When you press the function key once LCD will display one type of battery Step 3 After choosing the matched battery you need press the func...

Страница 14: ...w thermal fuses included in the scope of delivery 4 Close the solar charge controller as described in section Closing the solar charge controller 9 2 Cleaning the Cooling Fin Recommend PV open circuit...

Страница 15: ...essing When the controller abnormal please check the following question and contact the customer service representative 11 1 1 Controller failure mode Please check the fault tips in the failure mode a...

Отзывы: