V02.02
PFTAS Pty Ltd Pellet Fires Tasmania 7/1/2018
Pellet Heater User Manual - NB-Series
Страница 1: ...V02 02 PFTAS Pty Ltd Pellet Fires Tasmania 7 1 2018 Pellet Heater User Manual NB Series...
Страница 2: ...stat Temperature 11 f Automatic or Manual 11 g Check Temperatures 11 3 Setup reference guide 12 4 Setup Instructions Explained 13 a User control of the Combustion Fan Smoke fan and Room Fan speeds 13...
Страница 3: ...he NB Series pellet heater makes heating so easy The fire starts with a push of the switch or automatically with program and temperature control No matches or kindling or lugging heavy and dirty fire...
Страница 4: ...y determine the frequency of cleaning The use of high ash fuels may result in the heater needing to be cleaned daily A low ash fuel may allow longer intervals between cleaning CLINKERING clinkers are...
Страница 5: ...530 100 NB PA FS Grace Pellet Heater Console 4 13 170 90 30 1 0 2 3 100 670 770 610 110 NB PA 01 Grace Pellet Heater Insert 3 8 110 90 15 0 6 1 6 100 Out 1000 935 280 In 430 715 370 100 NB PA Grace P...
Страница 6: ...00 grams per hour on low and 1 8 kgs on high In reality these feed rates may be more or less depending on the pellet length Pellet heaters are designed to be reliable and not go out on the lowest sett...
Страница 7: ...is created in the firebox by a leak opening the front door a blocked flue or unsealed ash drawer the vacuum switch will sense it and cause the heater to go into a shutdown mode AUGER AND AUGER MOTOR...
Страница 8: ...warranty only covers appliances that are purchased from an authorized PFTAS dealer or distributor Refer to www pftas com au Service fees may apply if you seek warranty service from a dealer other than...
Страница 9: ...tons Start Up process commences Shutdown process commences Automatic Schedule Power Level Skip the process to stabilization Press pellet feed rate P1 2 3 4 Press to toggle from Auto to Man Thermostat...
Страница 10: ...button once and then again but hold until you hear a beep with the second push Message CLEANING will be shown first The exhaust system is flushed with air Message FEEDING will be shown next Pellets a...
Страница 11: ...own first Fuel feed stops pellets burn away After the temperature in the heater has cooled down GOODBYE is displayed STOPPED c Power Level Pellet Feed rate FLAME POWER VARIATION Pellet feed rate can b...
Страница 12: ...rate P1 P2 P3 or P4 until the actual room temperature exceeds the set point at which time the heater will automatically switch to the selected ECO Mode Turn off or run at minimum power f Automatic or...
Страница 13: ...the room fan Next Increase or decrease the combustion fan P2 Repeat Increase or decrease the room fan Next Increase or decrease the combustion fan P3 Repeat Increase or decrease the room fan Next Inc...
Страница 14: ...hen you will see poor combustion characterized by a lazy flame The glass will go black faster than normal and the heater will require more cleaning Pellets could also build up in the burn pot Adjust t...
Страница 15: ...4pm to 10pm Monday to Friday and OFF Saturday and Sunday so that MANUAL operation is used as required on those days f Setting the clock The hour minuets day month and year can be set to local time Pl...
Страница 16: ...rotection sensor over temperature Check room fan speed E7 Power failure Clear error code and resume operation E8 Blocked exhaust passages Heater needs to be serviced ESC1 Temperature sensor 1 is short...
Страница 17: ...fore and after each lighting You must check that the fire pot before and after each lighting Ensure it is clean and that no waste or residue blocks the holes in order to always guarantee excellent com...
Страница 18: ...nly once each season providing the correct fuel is used You should arrange for this when booking your annual service e Frequency of Component Cleaning Parts Frequency Daily 2 3 Days 30 Days Annually P...
Страница 19: ...is displayed Feed unit is blocked Clear the blockage No auger drive Contact customer support No fuel in the hopper Fill the hopper B Second stage ignites the pellets LIGHTING is displayed It is norma...
Страница 20: ...n domestic pellet heating market and are imported distributed and supported in Australia by PFTAS Pty Ltd trading as Pellet Fires Tasmania Contents of this manual may be updated without notice For the...