PFS BRO18NG Скачать руководство пользователя страница 5

5

CONNECTING GAS SUPPLY TO BURNER ASSEMBLY

Natural Gas applications only:

A. Place burner pan assembly in the center of the fireplace.
B. Attach 3/8” Flare X 1/2” NPT gas valve (Part #13) to the 1/2 inch gas supply stub already in fireplace.

Be certain connections are tight and use pipe compound on all male NPT (pipe) threads to seal

joints.

C. Attach 3/8” flared tubing (Part #15) to burner pan assembly.

.

Attach opposite end to gas supply line by

carefully bending the flared tubing as needed to make the connection. Avoid kinking thetubing while

NOTE:

A good method of bending the tube is to fill it with sand, bending the tube as needed to make th

e

connection.This method will eliminate kinking in the line. Once the tube is in the desired configuration,

be sure to

empty

the tube completely of any sand before tube is connected to the gas supply line and

D .

 

Be certain all connections are tight. Only use pipe compound on all male NPT (pipe) threads.

Test all connections with a soapy water solution, and with the gas supply turned on. If bubbles appear

on any connection, tighten and re-test. Once it is determined there are no leaks whatsoever, turn off 

gas supply and move to next assembly step.

GRANULE, EMBER AND GRATE PLACEMENT

A. Spread granules (Part # 16) over the installed burner pan. Granules

should be sloped to the same angle as the burner pan filling the entire

pan. (See Figure 7A.)

B. Spread glowing embers (Part # 17) evenly over the top of the granules

covering the entire surface area, concentrating on the front and sides

of the burner pan for the most realistic burning effect.

C. Place log grate (Part # 7) over the burner pan aligning as shown.

(See Figure 7B.) Note that the burner pan is just ahead of the loc-

D.Attach back log Standoff(Part # 18) to the back part of the grate.

(See Figure 7B.)

NOTE:

A hammer may be used to tap the back log stand-off in place.

It may be necessary to squeeze the back log stand-off with pliers after

attaching to the grate.

(Manual Valve / match lit only)

A. This appliance must be lighted by hand each time it is used. When lighting

     the burner, follow these instructions exactly.

 

Figure 7 ( A & B) Granule and

Grate Placement

Figure 8. Lighting the log set

bending. If tubing must be cut, use a tubing cutter. Flare the cut end of tube with a flaring tool.

burner assembly.

WARNING:

For installation in a solid-fuel burning fireplace only. The

ust have a permanent vent opening to atmosphere

inches, or as determined from the

manufacturer's installation instructions.

fireplace chimney m

of not less than 49.2 square

LIGHTING YOUR GAS LOG SET

ation of the log standoffs, with the front below the bend in the grate.

TO TURN OFF GAS TO APPLIANCE

Turn the manual gas control valve (

Figure 9

) clockwise

to the OFF position.

Figure 9. Example of

  Manual gas valve

   (MBV300 shown)

Open chimney flue damper to the full open position.

B.

Turn your gas control manual valve (

Figure 9)

clockwise

to the full

      OFF position.

  Wait five (5) minutes to clear out any gas. If you then smell gas, STOP!

Follow “A” in the safety Information above on this label. If you don't smell

      gas, go to the next step.

a burning match on the surface of the burner embers (See

Figure 8)

Do not hold match in hand

. Turn your manual gas valve counterclockwise

the ON position.

C.

D. 

Place

E.

Содержание BRO18NG

Страница 1: ...plier call the fire department Installation and service must be performed by a quali ed installer service agency or the gas supplier WARNING If the information in this manual is not followed exactly a...

Страница 2: ...19 INSTALLATION OPERATION MANUAL FIREPLACE GAS LOG INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference Do not store or use gasoline or other flammable vapo...

Страница 3: ...fireplace chimney must have a perman ent vent opening to atmosphere of not less than 49 2 square inches or as determined from the manufacturer s installation instructions WARNING If you do not follow...

Страница 4: ...See Figure 1 Parts List as a guide to reference part numbers BURNER PAN INSTALLATION NOTE Use pipe compound on all male threads to seal joints B Locate 3 8 locknut Part 12 and washer Part 21 and attac...

Страница 5: ...f the burner pan for the most realistic burning effect C Place log grate Part 7 over the burner pan aligning as shown See Figure 7B Note that the burner pan is just ahead of the loc D Attach back log...

Страница 6: ...LOG PLACEMENT MODEL BRO18NG Place log 1 onto back left area of the grate perpendicular to log 2 Place Y shaped log 4 onto left of the grate ahead of raised area Place log 3 at the front right of the g...

Страница 7: ...sed area Log Identification Back Log Stand Offs in place 1 2 3 4 6 7 8 9 on the grate finger left of center Place log 3 onto back left area of the grate perpendicular to log 1 Place log 4 at the front...

Страница 8: ...LOG PLACEMENT MODEL BRO24 Continued Place the two small logs 7 and 8 in front of the grate as shown 8...

Страница 9: ...ack log 3 onto raised area of the grate Log Identification Back Log Stand Offs in place 1 2 Place left front log 2 onto front area of the grate 3 4 5 6 Place Cross Log 4 at the center left Place Y sha...

Страница 10: ...L CSO24 CSO30 Continued Place Cross Log 8 at the top center across logs 5 and 7 Place Cross Log 7 at the center right Place log 9 in front of the set on the fireplace floor Make sure it is in front of...

Страница 11: ...o Back Log Stand Offs in place Back Log Stand Offs 1 2 3 4 5 6 Place Cross Log 3 at the left side Place Cross Log 4 at the center Place Cross Log 5 at the right side Place Cross Log 6 from the center...

Страница 12: ...e center Left 4 to the center right 5 logs 1 2 3 4 5 6 Log Identification MO24NG Follow the first five steps from MO18NG on previous page Place Cross Log 5 at the center right Place Y Shaped Cross Log...

Страница 13: ...te Place shorter back log 2 onto raised area of the grate 1 2 3 Log Identification Back Log Stand Offs in place Place Cross Log 3 at the left side Place Cross Log 4 at the right side Place Cross Log 5...

Страница 14: ...grate Place shorter back log 2 onto raised area of the grate Back Log Stand Offs in place Log Identification Place Cross Log 3 at the left side Place Cross Log 4 at the center left Place Cross Log 5...

Страница 15: ...osed open valve fully gas line partial obstruction inspect burner tube for kinks or obstructions log arrangement incorrect rearrange logs to specified pattern We recommend for the appliance and the fi...

Страница 16: ...f of purchase call the Customer Service Hotline for authorization to ship defective part prepaid and insured in original carton to Sure Heat Manufacturing 3140 Moon Station Road Kennesaw GA 30144 Good...

Отзывы: