5. Switch off the process- and pump-specific media supply (e.g. the sealing gas supply).

Procedure with contaminated medium

With media that heavily contaminate the suction chamber, flush the suction chamber with air or nitrogen 
at the end of the process.

1. Close the shut-off valve in the vacuum line and disconnect the vacuum pump from the process.
2. At the end of the process, continue to operate the vacuum pump with flushing gas supply at the 

vacuum flange for another approx. 20 to 40 minutes.

3. Then stop the flushing gas supply.
4. Switch off the vacuum pump.
5. Vent the vacuum pump via the intake side.
6. Make sure that you do not vent the vacuum chambers through the vacuum pump.
7. Switch off the process- and pump-specific media supply (e.g. the sealing gas supply).

6.6 Re-start (to)

NOTICE

Damage to the roots pump from significant temperature fluctuation

If the housing cools down too quickly due to external influences, there is a risk of contact being made 
between the rotor at warm operating temperature, and the colder pump housing. This will result in 
irreversible pump damage.

► Avoid uneven cooling, if you are going to switch the roots pump back on after a short period.
► Vent the roots pump in order to achieve a temperature compensation between the housing and 

rotor as quickly as possible.

Operation

37/56

Содержание OKTA 8000 G ATEX

Страница 1: ...OPERATING INSTRUCTIONS EN Original OKTA 8000 G Roots Pump...

Страница 2: ...eiffer vacuum de Further operating instructions from Pfeiffer Vacuum can be found in the Download Center on our website Disclaimer of liability These operating instructions describe all models and var...

Страница 3: ...ing with lubricant 21 5 3 Filling with sealing oil 22 5 4 Fill the sealing medium for the axial face seal 23 5 5 Connecting the vacuum side 24 5 6 Connecting the fore vacuum side 25 5 7 Connecting the...

Страница 4: ...ump 45 9 Malfunctions 47 10 Service solutions from Pfeiffer Vacuum 49 11 Spare parts 51 11 1 Set of seals for version with RSSR 51 11 2 Set of seals for version with axial face seal axial face seal se...

Страница 5: ...of the roots pumps 18 Tbl 5 Requirements on the cooling water composition 27 Tbl 6 Max permissible flushing quantity 36 Tbl 7 Maintenance intervals 39 Tbl 8 Troubleshooting 48 Tbl 9 Conversion table P...

Страница 6: ...pump with tubular gas cooler 26 Fig 9 Cooling water connection at the gas cooler 27 Fig 10 Delta connection for low voltage 29 Fig 11 Star circuit for high voltage 29 Fig 12 Check of direction of rota...

Страница 7: ...rd version Standard motor Housing and all parts forming the suction chamber are made of GGG Connection flanges are designed as ISO DIN or ANSI flanges Connections for sealing gas inlet Shaft sealed wi...

Страница 8: ...ers on the product along with their meaning Mod Okta 8000 G Weight 1500 kg 3 D 35641 Asslar Made in Germany Mod No PP G80 xxx n max 2200 1 min Oil P3 21 0 l S N max 12000 m h 09 2018 Ser No 12xxxxxxxx...

Страница 9: ...ling halves RSSR Radial shaft seal ring AFS Axial face seal GGG Spheroidal graphite cast iron FPM Fluoropolymer rubber PE Earthed conductor protective earth PN Nominal pressure stage pressure nominal...

Страница 10: ...y damage Notes tips or examples indicate important information on the product or on this document 2 2 Safety instructions All safety instructions in this document are based on the results of the risk...

Страница 11: ...em and that it is cooled down Wear protective equipment e g safety goggles and gloves CAUTION Risk of injury from bursting due to high pressure in the exhaust line Faulty or insufficient exhaust lines...

Страница 12: ...itching off the motor and can trap fingers and hands within their reach Wait until the vacuum pump comes to a complete standstill Secure the vacuum pump against re start CAUTION Danger of burns on hot...

Страница 13: ...Safety precautions Duty to provide information on potential dangers The product holder or user is obliged to make all operating personnel aware of dan gers posed by this product Every person who is in...

Страница 14: ...uum pump for vacuum generation only When pumping media with an oxygen concentration level of 21 only use perfluorinated syn thetic oils F5 as lubricant Depending on the process and if necessary use se...

Страница 15: ...r periodic forces act on the unit Use of the vacuum pump in potentially explosive atmospheres Use of the vacuum pump in areas with strong electrical magnetic or electromagnetic fields Use of the vacuu...

Страница 16: ...o 20 to 30 hPa When combined with other Roots pumps the final pressure can be lowered down to the medium vacuum range The direction of flow of the vacuum pumps is vertical from top to bottom so that a...

Страница 17: ...ng made of FPM is used on standard roots pump versions Alter natively depending on the process medium the inner radial shaft seal ring is also be made of PTFE In this case the housing seals are also e...

Страница 18: ...8 1 G 1 2 4 G 3 8 DIN DN 300 PN 10 DN 150 PN 10 DIN ISO NW 320 ISO F NW 160 ISO F Tbl 4 Features of the roots pumps 3 4 Shipment Okta G without motor Connection flange Seal for the connection flange...

Страница 19: ...ection flange once the pipes have been mounted Fill the gear and bearing chambers with lubricant only once the final installation position is reached Pfeiffer Vacuum recommends keeping the transport p...

Страница 20: ...not have any corrosion protection on the inside If you intend to store the roots pump for longer periods we recommend that you use a special corrosion protection agreed with us Procedure 1 Close both...

Страница 21: ...ir circulation 6 Keep both sight glasses freely accessible for checks and maintenance 7 Ensure that the motor rating plate remains accessible at all times for a clear view of the voltage and frequency...

Страница 22: ...el during operation in the final vacuum Fill level during operation within the marking on the sight glass Refilling the lubricant is carried out with the roots pump switched off and vented 5 3 Filling...

Страница 23: ...sary provide temperature monitoring for the event that the temperature exceeds the per missible value Also use water cooling at the sealing medium container for the event that the cooling is insuffi c...

Страница 24: ...ring assembly of the sealing medium container observe the installation instructions supplied by the manufacturer 2 Mount the sealing medium container at a height between 500 mm and max 800 mm above th...

Страница 25: ...exhaust lines cause hazardous situations e g increase in exhaust pressure There is a risk of bursting It is not possible to rule out the risk of injuries due to broken pieces flying around high escapi...

Страница 26: ...qual to the size of the connection nominal di ameter of the fore vacuum flange 4 When connecting the flanges observe the correct position of the seals 5 Maintain a tension free connection 5 8 Connecti...

Страница 27: ...nt free from grease and oil pH value 7 to 9 Carbonate hardness max 10 dH 12 53 e 17 8 fH 178 ppm CaC03 Chloride content max 100 mg l Sulfate content max 240 mg l Carbonic acid content max not detectab...

Страница 28: ...Set the required switching pressures minimum 300 hPa maximum 10000 hPa 5 9 Establishing mains connection DANGER Danger to life from electric shock Contact with exposed and live elements generate an e...

Страница 29: ...g a three phase motor with 6 pin terminal board NOTICE Risk of damage from high starting torque The specific load behavior of the vacuum pump requires direct on line starting at full motor power Engin...

Страница 30: ...tch the vacuum pump on briefly 2 to 3 seconds The motor and coupling must rotate clockwise see directional arrow on housing cover 3 If the direction of rotation is incorrect swap the 2 phases of the c...

Страница 31: ...vacuum pump always adhere to the direction of rotation regardless of the illustration in the wiring diagram The sense of rotation arrow on the vacuum pump indicates the rotation direction After shut...

Страница 32: ...tightening factor 2 5 Connecting sealing gas The use of sealing gas in the area of the shaft feedthroughs prevents the contamination of the lubricant when conveying solvents or reactive gases 1 We rec...

Страница 33: ...e locking screw of the measurement connection hole at the discharge channel 2 Mount the clamping screw fitting for the thermometer 3 Mount the filling pipe in the clamping screw fitting 4 Set the inst...

Страница 34: ...handling toxic substances Safely purge toxic process gases via an exhaust line Use suitable filter equipment to separate toxic substances CAUTION Danger of burns on hot surfaces Depending on the opera...

Страница 35: ...max permissible sealing gas pressure Reduce the sealing gas pressure to 1200 hPa Stop the sealing gas supply immediately after switching off the vacuum pump Equation for calculating the sealing gas f...

Страница 36: ...on the inside Pump type max flushing quantity Okta 500 G 0 5 l min Okta 1000 1500G 1 0 l min Okta 3000 4000 G 1 5 l min Okta 8000 G 2 0 l min Tbl 6 Max permissible flushing quantity 6 5 Switching off...

Страница 37: ...ump 5 Vent the vacuum pump via the intake side 6 Make sure that you do not vent the vacuum chambers through the vacuum pump 7 Switch off the process and pump specific media supply e g the sealing gas...

Страница 38: ...the drive motor from the mains 4 Secure the motor against switching back on 5 Remove the vacuum pump from the system if necessary 6 Dispose of used lubricant according to applicable regulations in ea...

Страница 39: ...ible with the process Change the lubricant and sealing oil Check the temperature sensor if installed Maintenance level 2 Check the coupling for damage replace the toothed ring if necessary Change the...

Страница 40: ...draining lubricant if it comes into contact with the skin Wear personal protective equipment Use a suitable collection receptacle Pfeiffer Vacuum recommends determining the precise service life of the...

Страница 41: ...level is reached see chapter Filling with lubri cant page 21 2 Screw in the lubricant filler screws Tightening torque max 50 Nm 7 4 Changing the sealing oil A sealing oil change is required for roots...

Страница 42: ...old state to max halfway Procedure for changing sealing oil 1 Open the filler flap on the oiler 2 Place the collection receptacle underneath 3 Unscrew the sealing oil drain screw 4 Fully drain the lub...

Страница 43: ...ween pistons and housing are within a tenth of a centimeter range Sustained accu mulating contamination has the following effect the friction heat inside the roots pump increases the power consumption...

Страница 44: ...coupling observe the installation instructions of the coupling manufacturer Procedure 1 Make sure that the prescribed installation dimension is observed precisely Angular and radial displacement of t...

Страница 45: ...The useful life of the lubricant is limited max 2 years Prior to recommissioning following a shut down of 2 years or more carry out the following work Observe the maintenance instructions consult Pfe...

Страница 46: ...Procedure Dispose of all substances safely according to local regulations Decommissioning 46 56...

Страница 47: ...Suction chamber con taminated 1 Clean suction chamber 2 If necessary contact Pfeiffer Vacuum Service Gear gear wheels damaged 1 Switch off the vacuum pump immedi ately 2 If necessary contact Pfeiffer...

Страница 48: ...di ately 2 Clean suction chamber Damage to the bear ing or gear wheels 1 Switch off the vacuum pump immedi ately 2 Contact Pfeiffer Vacuum Service Damage to motor bearing 1 Switch off the vacuum pump...

Страница 49: ...and addresses can be found on our website in the Pfeiff er Vacuum Service section Advice on the optimum solution is available from your Pfeiffer Vacuum contact partner For quick and smooth handling of...

Страница 50: ...containers e Observe the applicable transport conditions ERKL RUNG KONTAMINIERUNG 6 Affix the declaration of contamination to the outside of the packaging 7 Then send your product to your local Servi...

Страница 51: ...for the suction and pressure side 11 3 Axial face seal complete The set of seals contains the seal components with all corresponding O rings 11 4 Maintenance kit for version with RSSR The maintenance...

Страница 52: ...1 1 Pa 1 N m2 Tbl 9 Conversion table Pressure units mbar l s Pa m3 s sccm Torr l s atm cm3 s mbar l s 1 0 1 59 2 0 75 0 987 Pa m3 s 10 1 592 7 5 9 87 sccm 1 69 10 2 1 69 10 3 1 1 27 10 2 1 67 10 2 To...

Страница 53: ...with connected exhaust line 75 105 dB A Protection category IP55 Cooling method standard Gas cooled Sealing gas Yes Ambient temperature 5 40 C Shipping and storage temperature 10 C 40 C Operating flu...

Страница 54: ...DN 300 PN 10 DN 300 PN 10 DN 150 PN 10 M20 12x 285 240 M20 8x 482 6 400 Dichtrille sealary groove Innen inner dia 316 Au en outer dia 340 Tiefe depth 3 4 105 719 1384 30 120 600 490 45 A A Fig 19 Okta...

Страница 55: ...compilation of technical documents is Mr Sebas tian Oberbeck Pfeiffer Vacuum GmbH Berliner Stra e 43 35614 A lar Germany Roots pump Okta 8000 G Harmonized standards and applied national standards and...

Страница 56: ...PW0263 ed G Date 1901 P N PW0263BEN...

Отзывы: