DC out
S1
TPS / DCU
Electronic
Drive Unit
DC in
PM 061 352 -T
Fig. 19:
Connecting the electronic drive unit to a power supply pack
Connecting the electronic drive unit
1. Make sure that you have the correct supply voltage.
2. Make sure that the power supply pack main switch is off prior to connection.
3. Use a suitable connection cable from the Pfeiffer Vacuum accessories range.
4. Insert the connecting cable into the connection "DCin" on the electronic drive unit and close the
bayonet lock.
5. Insert the connecting cable into the connection "DCout" on the power supply pack and close the
bayonet lock.
Installation
34/62