background image

NOTICE

Property damage from intake of solid particles

During commissioning, there is a risk of damage to the suction chamber from dirt from the system or 
the pipes.

► Use a suitable protective strainer ("start-up strainer") in the intake flange.
► Ensure that this strainer is only removed when the risk of solid particles entering the vacuum 

pump can be excluded.

– Observe any pumping speed decrease.

Required tools

● Ring spanner, 

WAF 13

 with flange DN 160 ISO-F

● Ring spanner, 

WAF 30

 with flange DN 150 PN16

Connecting the vacuum side

1. Degrease the connection flange.
2. Clear welded lines of any scaling, loose particles etc. prior to installation.
3. Route the piping between the vacuum pump and vacuum chamber so that it remains as short as 

possible; at a minimum, the nominal diameter of the pump flange.

4. Select a larger nominal diameter for pipe lengths > 5 m.
5. Support or suspend the piping to the vacuum pump so that no piping system forces act on the 

vacuum pump.

6. Always use 

all

 prescribed bolts for fastening the flanges and consider the prescribed pressure 

stage for PN 16.

5.5 Use splinter shield

Pfeiffer Vacuum centering rings with splinter shield in the vacuum flange protect the roots pump against 
foreign particles from the vacuum chambers. The pumping speed is reduced according to the passage 
guide values and the size of the vacuum flange.

1

Fig. 11:

Splinter shield mounting orientation

1
Splinter shield

Procedure

► When installing the vacuum flange, pay attention to the correct mounting orientation of the splinter 

shield.

Installation 

26/66

Содержание HILOBE 2704

Страница 1: ...OPERATING INSTRUCTIONS EN Translation of the Original HILOBE 2704 4504 6204 Roots pump...

Страница 2: ...eiffer vacuum de Further operating instructions from Pfeiffer Vacuum can be found in the Download Center on our website Disclaimer of liability These operating instructions describe all models and var...

Страница 3: ...ng orientations 20 3 2 Identifying the product 20 3 3 Product features 20 3 4 Scope of delivery 20 4 Transportation and Storage 21 4 1 Transporting the vacuum pump 21 4 2 Store the vacuum pump 22 5 In...

Страница 4: ...e 44 9 1 Maintenance information 44 9 2 Checklist for inspection and maintenance 44 9 3 Cleaning the air filter 46 9 4 Changing the lubricant 46 9 4 1 Draining the lubricant 47 9 4 2 Filling with lubr...

Страница 5: ...iguration with parameters P 019 and P 024 40 Tbl 14 Configuration with parameters P 060 and P 061 40 Tbl 15 Meaning of the LEDs 42 Tbl 16 Maintenance intervals 45 Tbl 17 Troubleshooting 52 Tbl 18 Erro...

Страница 6: ...ction of flow 24 Fig 9 Mounting orientation Horizontal direction of flow 24 Fig 10 Filling with lubricant 25 Fig 11 Splinter shield mounting orientation 26 Fig 12 Connect the switch box 28 Fig 13 Conn...

Страница 7: ...iffer Vacuum Download Center 1 1 2 Variants HiLobe 2704 HiLobe 4504 HiLobe 6204 HiLobe 2704 H HiLobe 4504 H HiLobe 6204 H 1 2 Target group These operating instructions are aimed at all persons perform...

Страница 8: ...e The rating plate for the vacuum pump is located on the metal casing near the motor connection plug D 35641 Asslar Mod RC 7500 IP 54 Type 12 P N PP 200 075 S N 12345637 Input 3 380 480 V 10 50 60 Hz...

Страница 9: ...rews Tbl 1 Stickers on the product 7 1 2 6 5 3 4 Fig 1 Position of stickers on product with vertical direction of flow 1 Warranty seal 5 Warning notice hot surface 2 Rating plate of the electronic dri...

Страница 10: ...it P xxx Electronic drive unit control parameters Printed in bold as a three digit number in square brackets Frequently displayed in conjunction with a short description Example P xxx Software version...

Страница 11: ...perty Notes tips or examples indicate important information about the product or about this docu ment 2 2 Safety instructions All safety instructions in this document are based on the results of the r...

Страница 12: ...uitable motor protection switch Obtain the power details for the setting value from the motor rating plate WARNING Risk of fatal injury due to electric shock on account of incorrect installation The d...

Страница 13: ...itable touch protection in system solutions Risks during operation WARNING Danger of poisoning due to toxic process media escaping from the exhaust pipe During operation with no exhaust line the vacuu...

Страница 14: ...n of devices or parts of them During maintenance work there is a risk to health from contact with these poisonous substances Illegal disposal of toxic sub stances causes environmental damage Take suit...

Страница 15: ...max 2000 m above sea level1 Installation surface flatness horizontal max permissible angle of inclina tion 3 Ambient temperature 5 to 40 Relative humidity of air max 85 Permanent intake pressure in ci...

Страница 16: ...parameters in the electronic drive unit Using lubricants not specified by Pfeiffer Vacuum Using pipes to lift the vacuum pump Use of accessories or spare parts that are not listed in these instructio...

Страница 17: ...s guidelines and laws referred to in this documentation The above individuals must have expressly granted operational authorization to commission program configure mark and earth devices systems and c...

Страница 18: ...the opposing synchronous running of the roots pistons Lubrication is limited to the two bearing and gear chambers which are arranged separately from the suction chambers Scan the QR code or click her...

Страница 19: ...al Temp exhaust gas optional Temp 2 Fan 1 n c cooling water mon optional Fan 2 8 6 2 7 3 4 5 1 Fig 6 Design switch box 1 Switch box 5 Sensor connections 2 Operator panel 6 Motor connection 3 Fan grill...

Страница 20: ...s shown on the rating plate Pump model Model number Type and quantity of the lubricant Max allowable pump rotation speed Date of manufacture Input voltage range 3 3 Product features Pump type Nominal...

Страница 21: ...e the flange covers for the connection flange once the pipes have been mounted Fill the gear and bearing chambers with lubricant only once the final installation posi tion is reached Packing Pfeiffer...

Страница 22: ...in the roots pump interior are provided with corrosion protection Storage Pfeiffer Vacuum recommends storing the products in their original transport packaging Procedure Close both connection flanges...

Страница 23: ...installation location 2 Ensure the prescribed mounting orientation of the vacuum pump before the vacuum pump is filled with lubricant for the first time 3 Place the vacuum pump on a flat horizontal a...

Страница 24: ...ed Use approved lubricant only Use alternative application specific lubricants only following consultation with Pfeiffer Vacuum The lubricant type is specified on the rating plate Please refer to rati...

Страница 25: ...th the pump to be able to place a collection re ceptacle for the lubricant 2 Unscrew the filler screws 3 Hold the fill level limiter with the ring spanner and unscrew the drain screw at the same time...

Страница 26: ...m pump and vacuum chamber so that it remains as short as possible at a minimum the nominal diameter of the pump flange 4 Select a larger nominal diameter for pipe lengths 5 m 5 Support or suspend the...

Страница 27: ...damage caused by regenerative energy produced with rotation of the piston Equip the vacuum pump with a facility that prevents the backflow of gases Use e g a shut off facility on the fore vacuum side...

Страница 28: ...itch box or when the pistons are running never disconnect the motor connecting plug After switching off wait at least another 5 minutes until the capacitors have discharged before separating the cable...

Страница 29: ...device mains switch Install a suitable motor protection switch Obtain the power details for the setting value from the motor rating plate Installing the mains disconnection device 1 The power details...

Страница 30: ...ction for the radio reception Ensure that the vacuum pump is connected only to a supply terminal featuring a short circuit capacity of Ssc 351 If necessary consult the distribution network operator Th...

Страница 31: ...15 pin Pin Function Description factory setting 1 n c 2 DI access request V Control via DIs GND open Control unlocked 3 DI1 V Rotation speed setting mode GND open no rotation speed setting mode 4 n c...

Страница 32: ...feiffer Vacuum parameter set via the RS 485 interface description relates to factory set tings DO1 Pin 8 V No errors After applying the voltage supply the digital output DO1 permanently outputs V mean...

Страница 33: ...85 converter PC D Sub 1 2 3 4 Fig 16 Cross link via connection RS 485 using connection cables and accessories 1 Connection cable with RS 485 3 M12 to M12 extension cable 2 Y connector for RS 485 4 USB...

Страница 34: ...1 0 n2 n1 n0 0 6 N O _ D E F c2 c1 c0 cR _ R A N G E _ L O G I C NO_DEF Parameter number n2 n0 no longer exists _RANGE Data dn d0 outside the permissible range _LOGIC Logical access error 6 3 3 Telegr...

Страница 35: ...10 2 005E8 is equivalent to 5 108 4 string Any character string with 6 charac ters ASCII codes between 32 and 127 06 TC_110 TM_700 6 boolean_new Logical value false true 01 0 is equivalent to false 1...

Страница 36: ...ting of the parameter for the use with the Pfeiffer Vacuum protocol Access type R read Read access W write Write access Unit Physical unit of the described variable min max Permissible limit values fo...

Страница 37: ...ing hours 1 R h 312 Fw version Software version interface cir cuit board 4 R 313 DrvVoltage Supply voltage Voltage in V 2 R V 315 Nominal Spd Nominal rotation speed Hz 1 R Hz 316 DrvPower Drive power...

Страница 38: ...5 Additional parameter for the DCU Additional parameter in the control panel The basic parameter set is set in the electronic drive unit ex factory For controlling con nected external components e g v...

Страница 39: ...e vacuum pump from sucking in contaminants using suitable measures e g dust filter 3 Check the vacuum pump for visible damage and put the vacuum pump into operation only in a correct state 4 Make sure...

Страница 40: ...a an external control unit Operation via RS 485 and Pfeiffer Vacuum display and control unit or PC Automatic start After bypassing the contacts at pins 2 7 and 5 on the remote connecting plug or when...

Страница 41: ...f the vacuum pump in the range of 25 to 100 of the nominal speed The factory configuration for stand by is 30 Stand by operation has priority over rotation speed setting mode Set the stand by rotation...

Страница 42: ...e level is in the area at the center of the sight glass 3 Check operating fluid fill level daily during continuous operation and every time vacuum pump is switched on 8 6 Switching off and venting WAR...

Страница 43: ...e g the sealing gas supply Alternative Switch off via the Pfeiffer Vacuum parameter Set the parameter P 010 to the value 0 Procedure with contaminated medium 1 Close the shut off valve in the vacuum...

Страница 44: ...of our service training offering When ordering spare parts specify the information on the nameplate Cleaning and maintenance work Cleaning changing the air filter Cleaning the suction chamber and root...

Страница 45: ...acoustic pump test Checking the lubricant level and color of the lubricant Checking the vacuum pump for leaks Checking the vacuum pump for noises quiet running Maintenance level 1 lubricant replaceme...

Страница 46: ...nging the lubricant there is a health hazard due to contact with poisonous substances Illegal disposal of toxic substances causes environmental damage Wear suitable personal protective equipment when...

Страница 47: ...ricant in addition to the drain screw also unscrew the fill level limiter on the pump bottom side 1 Make sure that there is sufficient space underneath the pump to be able to place a collection re cep...

Страница 48: ...icant 1 Screw the fill level limiter back in 2 Place a collection receptacle under each drain 3 Fill the lubricant on both sides up to the maximum fill level Once full lubricant overfills the fill lev...

Страница 49: ...recommend you carry out maintenance and a lu bricant change prior to recommissioning 10 Please note the vacuum pump may not be stored in the vicinity of machines traffic routes etc as strong vibration...

Страница 50: ...n accordance with the applica ble regulations relating to environmental protection and human health with a view to reducing natural resource wastage and preventing pollution 11 1 General disposal info...

Страница 51: ...you can find information about potential causes and how to fix them here Problem Possible causes Remedy The vacuum pump does not start up and no LED lights up on the opera tor panel of the electronic...

Страница 52: ...on speed Error in the frequency converter FC Contact Pfeiffer Vacuum Service Err002 Motor excess voltage Error in the frequency converter FC Contact Pfeiffer Vacuum Service Parameter 13 was not activa...

Страница 53: ...cuum pump excess temperature Insufficient cooling Improve the cooling Check the operating conditions Observe the intended use Tbl 19 Warning messages of the electronic drive unit 12 4 Warning and erro...

Страница 54: ...ity You can find more detailed information and addresses on our homepage in the Pfeiffer Vacuum Service section You can obtain advice on the optimal solution for you from your Pfeiffer Vacuum represen...

Страница 55: ...duct in suitable stable transport containers only e Maintain applicable transport conditions ERKL RUNG KONTAMINIERUNG 6 Attach the contamination declaration to the outside of the packag ing 7 Now send...

Страница 56: ...t packages Pump version Order number Maintenance kit 1 HiLobe 2704 HiLobe 2704 H HiLobe 4504 HiLobe 4504 H HiLobe 6204 HiLobe 6204 H PP E47 100 T Maintenance kit 3 HiLobe 2704 HiLobe 2704 H HiLobe 450...

Страница 57: ...kage for HPU PM 061 005 T USB RS 485 converter PM 061 207 T Interface cable M12 m straight M12 m straight PM 061 283 T Interface cable M12 m straight M12 m angled PM 061 791 T DCU 002 Display Control...

Страница 58: ...Hg 1 33 1 33 10 3 133 32 1 33 0 133 1 1 Pa 1 N m2 Tbl 24 Conversion table Pressure units mbar l s Pa m3 s sccm Torr l s atm cm3 s mbar l s 1 0 1 59 2 0 75 0 987 Pa m3 s 10 1 592 7 5 9 87 sccm 1 69 10...

Страница 59: ...connection 3 380 480 V AC 10 50 60 Hz 3 380 480 V AC 10 50 60 Hz 3 380 480 V AC 10 50 60 Hz Rated power at max rotation speed 3 5 kW 5 5 kW 7 5 kW Recommended on site electric fuse protection 23 A 23...

Страница 60: ...m s 1 10 6 Pa m s Mains connection 3 380 480 V AC 10 50 60 Hz 3 380 480 V AC 10 50 60 Hz 3 380 480 V AC 10 50 60 Hz Rated power at max rotation speed 3 5 kW 5 5 kW 7 5 kW Recommended on site elec tric...

Страница 61: ...8x M20 8x 140 140 354 182 430 2 2 5 n200 n240 G 3 8 2x G 3 8 2x 275 5 263 5 n200 n240 DN 160 ISO F DN 150 PN16 M20 8x M10 8x 133 G 3 8 4x G1 2 4x M20 8x DN 160 PN16 DN 150 ISO F M10 8x Fig 20 HiLobe...

Страница 62: ...10 5 DN 160 ISO F DN 150 PN16 G 3 8 4x 162 200 2 2 5 2 2 5 240 200 M10 8x M20 8x 133 465 430 263 5 279 5 DN 160 ISO F DN 150 PN 16 M10 4x G 3 8 2x G 3 8 2x G 3 8 2x M10 8x M20 8x Fig 21 HiLobe 2704 H...

Страница 63: ...3 phase PE max 23 A 433 410 410 522 300 338 352 440 motor cable connection wall holder optional included in the delivery Fig 22 Electronic drive unit RC 7500 Technical data and dimensions 63 66...

Страница 64: ...delegated directive 2015 863 EU Harmonized standards and applied national standards and specifications DIN EN ISO 12100 2011 DIN EN 61010 1 2011 DIN EN 1012 2 2011 12 DIN EN 61000 3 11 DIN EN ISO 1385...

Страница 65: ...65 66...

Страница 66: ...Notizen Notes...

Страница 67: ......

Страница 68: ...PW0333 ed C Date 2102 P N PW0333BEN...

Отзывы: